Concurrent phakic intraocular lens explantation and phacoemulsification with IOL implantation: A retrospective analysis of efficacy and safety. [PDF]
Fathima TZ +3 more
europepmc +1 more source
Human macrophage adhesion is significantly higher on SIBS based glaucoma microshunts than on common intraocular lens materials in vitro. [PDF]
Dirk B +4 more
europepmc +1 more source
Secondary Carlevale Intraocular Lens implantation combined with 25-gauge pars plana vitrectomy and sulfur hexafluoride (SF6) for retinal detachment: a retrospective study. [PDF]
Pignatelli F +8 more
europepmc +1 more source
Efficacy Analysis of Capsular Tension Ring Ciliary Sulcus Suture Fixation for Lens Subluxation
Lan X, Bai H, Teng Y, Sun J, Wu X.
europepmc +1 more source
Related searches:
Extraction of an Acrylic IOL Through IOL Refolding
2022Gabor B Scharioth, Scharioth Gabor B
exaly +2 more sources
Collagen IOLs: A Suggestion for IOL Biocompatibility
European Journal of Implant and Refractive Surgery, 1991Abstract In order to study the effects of IOL surface modification on lens epithelial cell metaplasia, we implanted IOLs made of either PMMA or collagen IV in the capsular bag of pigmented, adult rabbit eyes following endocapsular phacoemulsification. The anterior capsule was not removed.
Kensaku Miyake +3 more
openaire +1 more source
Abstract Prompted by four cases of IOL power mislabelling, a method was developed which allowed the measurement of the IOL power using a keratometer. The principle of operation was to measure the curvature of the steepest surface of the IOL through a minus lens by which the size of the mires was brought into the measuring range of the keratometer. With
T, Olsen, H, Olesen
openaire +2 more sources
Dislocated IOL: Extraction of IOL and Implantation of Iris-Fixated IOL with 27G
2015The following chapter reports step by step the surgical procedure for a dislocated IOL. The surgery for a subluxated and a completely luxated IOL is described.
Ulrich Spandau, Mitrofanis Pavlidis
openaire +1 more source
IOL-Austausch nach IOL-Trübung, Techniken
2016Hintergrund: Eine IOL-Trübung nach Katarakt-Operation stellt in vielen Fällen eine Notwendigkeit zum IOL-Austausch dar. Wir haben untersucht, in wie vielen Fällen bei einem IOL-Austausch nach im Durchschnitt vor 3,4 Jahren erfolgter Kataraktoperation der Erhalt des Kapselsacks und eine[zum vollständigen Text gelangen Sie über die oben angegebene URL]
Cubuk, IY, Cordes, AK, Türkdamar, E
openaire +1 more source
Abstract. The intraocular lens (IOL) implant can be looked upon as a probe into the space of the eye. Adapting that view, it is logical to furnish the IOL‐probe with biomedical sensors that would explore its environment. A sensor is presented for continuous monitoring of intraocular pressure (IOP), incorporated in the haptics of an IOL.
B, Svedbergh +3 more
openaire +2 more sources