Results 111 to 120 of about 30,708 (215)

Markerless OP-Assistenz mit IOL-Master, Lumera 709 und Callisto

open access: yes, 2014
Fragestellung: Erste Ergebnisse der neuen markerless OP-Assistenz zeigen Praktikabilität und Effektivität. Methodik: Prospektive Studie für die Rhexiszentrierung mit Tinten-Markierung und Markless-Funktion. Gruppe 1 (Stiftmarkierung, sitzend im OP) und 2 (Markless), jeweils 10 Augen.[for full text, please go to the a.m. URL]
openaire   +2 more sources

ABERROMETRY CHANGES AND IOL DISLOCATION

open access: yesОфтальмохирургия, 2015
Purpose. To study the aberrometric changes in eyes with posterior IOL decentration. Material and methods. All ophthalmic examinations were performed including Hartmann-Shack WASCA and CRS-Master aberrometry system (Carl Zeiss Meditec).
A. B. Kachanov, A. A. Varavka
doaj  

Does Frontalis Sling Surgery for Congenital Ptosis Change the Corneal Topography and Refractive Characteristics Postoperatively?

open access: yesClinical Ophthalmology, 2020
Aastha Gandhi,1 Anuj Mehta,1 Mayuresh Naik2 1Department of Ophthalmology, V.M.M.C & Safdarjung Hospital, Ansari Nagar, New Delhi 110029, India; 2Department of Ophthalmology, H.I.M.S.R & H.A.H.
Gandhi A, Mehta A, Naik M
doaj  

Aberrometry changes and IOL dislocation

open access: yesОфтальмохирургия, 2013
Purpose. To study the aberrometric changes in eyes with posterior IOL decentration. Material and methods. All ophthalmic examinations were performed including Hartmann-Shack WASCA and CRS-Master aberrometry system (Carl Zeiss Meditec).
A.B. Kachanov, A.A. Varavka
doaj  

Estudi comparatiu de diferents lents intraoculars tòriques per a pacients operats de cataractes [PDF]

open access: yes, 2016
L’objectiu principal del present estudi és realitzar una comparativa entre diverses lents intraoculars (LIOs) tòriques que ja es troben comercialitzades per valorar el seu resultat pel que fa a la correcció d’astigmatismes cornials preoperatoris i a la ...
Roig Valero, Silvia
core   +1 more source

Comparison of Ocular Biometry and Refractive Outcomes Using IOL Master 700, IOL Master 500, and Ultrasound

open access: yesJournal of the Korean Ophthalmological Society, 2017
Tae Keun Yoo   +5 more
openaire   +1 more source

Estudio comparativo entre los biómetros ópticos IOL Master 500 versus IOL Master 700 en pacientes con catarata y análisis de repetibilidad [PDF]

open access: yesRevista Mexicana de Oftalmología, 2019
Roberto González-Salinas   +5 more
openaire   +1 more source

Comparison between ANTERION and IOL MASTER 500 in Cataract Surgeries

open access: yes
This research aimed to compare the measurements recorded by a traditional PCI technology biometer (Partial Coherence Interferometry) and by a SS-OCT (Swept Source Optical Coherence Tomography) technology machine in preoperative screening of patients with age-related cataract.
Evangelos Gkoumas   +5 more
openaire   +1 more source

The comparison of white-to-white via triple person-times caliper measuring and machine-measuring in V4c implantable collamer lens implantation

open access: yesScientific Reports
This study aimed to compare the differences and characteristics of white-to-white (WTW) values obtained before V4c implantation using triple person-times caliper, IOL-Master 700, Pentacam HR, and UBM, and to assess their correlation with vaulting.
Ting-Ting Dan   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy