Results 161 to 170 of about 21,399 (198)
Some of the next articles are maybe not open access.
Journal of Refractive Surgery, 2015
PURPOSE: To compare posterior capsule opacification (PCO) of a hydrophobic acrylic heparin surface modified intraocular lens (HSM-IOL) and an uncoated IOL (UC-IOL) 1 year after implantation. METHODS: One hundred two eyes of 51 patients underwent routine phacoemulsification with ...
Sarah Moussa +2 more
exaly +3 more sources
PURPOSE: To compare posterior capsule opacification (PCO) of a hydrophobic acrylic heparin surface modified intraocular lens (HSM-IOL) and an uncoated IOL (UC-IOL) 1 year after implantation. METHODS: One hundred two eyes of 51 patients underwent routine phacoemulsification with ...
Sarah Moussa +2 more
exaly +3 more sources
Current Eye Research, 2012
To compare the intensity of posterior capsule opacification (PCO) between two intraocular lenses (IOLs) of the same optic material, but with different haptic design (1-piece vs. 3-piece).This prospective intraindividual controlled cohort study comprised eighty eyes of 40 patients with bilateral age-related cataract. Each patient received a Polylens Y10
Georgios, Mylonas +5 more
openaire +2 more sources
To compare the intensity of posterior capsule opacification (PCO) between two intraocular lenses (IOLs) of the same optic material, but with different haptic design (1-piece vs. 3-piece).This prospective intraindividual controlled cohort study comprised eighty eyes of 40 patients with bilateral age-related cataract. Each patient received a Polylens Y10
Georgios, Mylonas +5 more
openaire +2 more sources
British Journal of Ophthalmology, 2013
To evaluate and compare the 1-year postoperative levels of posterior capsule opacification (PCO) as well as the level of anterior capsule retraction and opacification (ACO) after implantation of two single-piece hydrophobic acrylic intraocular lens (IOL) models.Randomised, controlled, prospective and double-blind study including 148 eyes of 74 patients
Guenal, Kahraman +6 more
openaire +2 more sources
To evaluate and compare the 1-year postoperative levels of posterior capsule opacification (PCO) as well as the level of anterior capsule retraction and opacification (ACO) after implantation of two single-piece hydrophobic acrylic intraocular lens (IOL) models.Randomised, controlled, prospective and double-blind study including 148 eyes of 74 patients
Guenal, Kahraman +6 more
openaire +2 more sources
Introduction: Posterior capsule opacification (PCO) remains the most common long-term complication of modern cataract surgery, leading to visual degradation and necessitating Nd:YAG laser capsulotomy. The risk of PCO is influenced by intraocular lens (IOL) characteristics, including material, optic edge design, and haptic configuration.
null Agnes Poppy Melina +2 more
exaly +2 more sources
Posterior Capsule Opacification with Microincision (MICS) IOLs
2014The history of cataract has been of continual evolution towards smaller and smaller incision sizes, but there is, however, little point in reducing incision size unless intraocular lenses (IOLs) can be designed to be inserted without the need to enlarge the incision.
openaire +1 more source
Contact Lens and Anterior Eye, 2009
The purpose of this study was to evaluate the in situ relationship of ThinOptX intraocular lens (IOL) in a cadaveric donor eye with posterior capsular opacification (PCO), following report of high PCO rates with this IOL. A cadaveric donor eye implanted with ThinOptX IOL and received at our eye bank was fixed in 10% formalin after retrieval of ...
Sameer, Kaushal +3 more
openaire +2 more sources
The purpose of this study was to evaluate the in situ relationship of ThinOptX intraocular lens (IOL) in a cadaveric donor eye with posterior capsular opacification (PCO), following report of high PCO rates with this IOL. A cadaveric donor eye implanted with ThinOptX IOL and received at our eye bank was fixed in 10% formalin after retrieval of ...
Sameer, Kaushal +3 more
openaire +2 more sources
[Histopathological study of rabbit anterior capsule opacification after IOL surgery].
Nippon Ganka Gakkai zasshi, 1993We investigated the histopathology of anterior capsular opacification after intraocular lens (IOL) implantation in a rabbit eye. Sixteen eyes of eight albino rabbits underwent continuous circular capsulorhexis, phacoemulsification, and in-the-bag IOL implantation.
Y, Tanaka, N, Ibaraki, M, Hongoh
openaire +1 more source
Anterior capsule opacification: a histopathological study comparing different IOL styles.
Ophthalmology, 2000To compare the degree of anterior capsule opacification (ACO) in human eyes obtained post-mortem containing various rigid and foldable posterior chamber intraocular lens (PC-IOL) designs.Comparative autopsy tissue study with clinicopathologic correlations.Four hundred sixty human globes containing the following PC-IOL styles were analyzed: (1) one ...
L, Werner +5 more
openaire +1 more source
International Ophthalmology
To evaluate the incidence, timing, and clinical characteristics of posterior capsule opacification (PCO) and Nd:YAG laser capsulotomy after uneventful cataract surgery with implantation of the ENOVA GF3 single-piece hydrophobic acrylic intraocular lens (IOL).In this retrospective study, the medical records of patients with a minimum of 6 months follow ...
Asli Kirmaci Kabakci +2 more
openaire +2 more sources
To evaluate the incidence, timing, and clinical characteristics of posterior capsule opacification (PCO) and Nd:YAG laser capsulotomy after uneventful cataract surgery with implantation of the ENOVA GF3 single-piece hydrophobic acrylic intraocular lens (IOL).In this retrospective study, the medical records of patients with a minimum of 6 months follow ...
Asli Kirmaci Kabakci +2 more
openaire +2 more sources

