Results 71 to 80 of about 5,882,083 (201)
Intraocular Lens Power Calculation in Challenging Cases [PDF]
In this article, we reviewed recently published papers of intraocular lens (IOL) power calculation in special eyes. In short eyes, accurate estimation of effective lens position is critical, and the ZEISS artificial intelligence IOL calculator produces ...
Ma, Jack X, Wang, Li, Koch, Douglas D
core +1 more source
ABSTRACT Background To determine whether axial length‐related magnification correction in optical coherence tomography angiography (OCTA) improves machine learning classification of high myopia and resolves inconsistencies in the values and discriminatory power of OCTA microvascular metrics.
Danuta M. Sampson +9 more
wiley +1 more source
IOL Power Calculation in Short and Long Eyes
An analysis of the studies published in the past 50 years reveals that the Haigis, Hoffer Q, and Holladay 2 formulas are the best options for intraocular lens power prediction in short eyes (26 mm), the Barrett Universal II, Haigis (with optimized constants), Olsen, and SRK/T formulas provide the most accurate outcomes for intraocular lens power ...
Kenneth J, Hoffer, Giacomo, Savini
openaire +2 more sources
ABSTRACT Aim To compare maternal and neonatal outcomes of induction strategies initiated with slow‐release vaginal dinoprostone (10 mg) or balloon catheter in multiparous women undergoing term induction of labor with an unfavorable cervix. Methods This retrospective cohort study included 802 multiparous women with singleton pregnancies at ≥ 37 weeks ...
Raneen Abu Shqara +5 more
wiley +1 more source
Identification of Variants in Two Families With Congenital Cataract by Whole Exome Sequencing
We describe likely pathogenic missense variants causing congenital cataract and investigate these variants using high‐throughput gene sequencing, Sanger sequencing, bioinformatics, and computational biology tools. Our findings provide novel insights into the molecular diagnosis of congenital cataract and have important implications for genetic ...
Yazhou Huang +8 more
wiley +1 more source
Ophthalmometry in IOL power calculation: videokeratographic versus Javal ophthalmometric data.
Ophthalmometry in IOL power calculation: videokeratographic versus Javal ophthalmometric ...
N. Lugli +3 more
core
ABSTRACT Systematic studies on the fatigue deformation and damage mechanisms of nickel‐based single‐crystal superalloys (Ni‐SXs) under combined thermal and mechanical conditions remain limited, particularly regarding the influence of strain amplitude on the relative contributions of fatigue and oxidation damage.
Liyin Zhang +7 more
wiley +1 more source
ABSTRACT Despite sustained efforts to promote speaking up in healthcare, improvements remain ephemeral. In diverse clinical learning and practice environments shaped by generational, cultural, professional and pedagogical plurality, speaking up operates as a situated social practice. Adopting an interpretive bricolage, we conducted a critical discourse
Shaista Salman Guraya +6 more
wiley +1 more source
Comparison of IOL power calculations by the IOLMaster vs theoretical calculations [PDF]
This study evaluates the agreement between the calculations performed by IOLMaster and as performed according to the published methods, for three formulas, Holladay I, Hoffer Q, and SRK-T.Hypothetical and identical data were used as input variables for calculations by IOLMaster and by a computer program written in visual basic to perform calculations ...
openaire +2 more sources
The effect of corneal power on the accuracy of 14 IOL power formulas
Background This study evaluates the impact of corneal power on the accuracy of 14 newer intraocular lens (IOL) calculation formulas in cataract surgery.
Jialin Xu +10 more
doaj +1 more source

