Results 71 to 80 of about 1,908 (178)

Swept-Source Optical Coherence Tomography Biometer as Screening Strategy for Macular Disease in Patients Scheduled for Cataract Surgery [PDF]

open access: yes, 2019
The aim of this study was to assess the central macular imaging captured with an optical biometer based on full-eye-length Swept-Source OCT (SS-OCT) scan as a screening strategy for identifying macular diseases in patients scheduled for cataract surgery.
Belfanti, L.   +8 more
core   +1 more source

The need for cycloplegic refraction in adolescents and young adults [PDF]

open access: yes, 2023
Cycloplegic refraction is considered the gold standard method when examining children and for ensuring accurate refractive error assessment within epidemiological studies.
Baraas, Rigmor C.   +2 more
core   +1 more source

A review of angle kappa and multifocal intraocular lenses and their effect on visual outcomes

open access: yesActa Ophthalmologica, Volume 104, Issue 2, Page e122-e138, March 2026.
Abstract Although most patients are satisfied with their vision after multifocal intraocular lens (IOL) implantation, dissatisfaction has been reported for various reasons, including poor visual outcomes and visual disturbances. Many published reports hypothesise that preoperative angle kappa may be an associated factor in patient dissatisfaction ...
Thomas Kohnen   +2 more
wiley   +1 more source

Comparison of Simulated and True Keratometry Measurements Using Swept-Source Optical Coherence Tomography and Dual Scheimpflug–Placido Imaging

open access: yesJournal of Ophthalmology, 2021
Purpose. To compare simulated and total keratometry and corneal astigmatism values between the IOLMaster 700 and Galilei G4 devices. Methods. A retrospective chart review was conducted for all patients undergoing phacoemulsification by a single surgeon ...
Elizabeth A. Urias   +2 more
doaj   +1 more source

A two‐step formula constant optimization strategy for minimal standard deviation and zero mean prediction error in IOL power calculation

open access: yesActa Ophthalmologica, Volume 104, Issue 2, Page 181-192, March 2026.
Abstract Purpose To investigate the precision and accuracy performance of a two‐step approach for optimizing lens formula constants (FC) with a refractive offset correction (RO) as a second tuning parameter. Methods Using IOLMaster 700 biometric data from 4 datasets (886/613/821/467 eyes treated with the Hoya Vivinex/Johnson&Johnson ZCB00/Alcon SA60AT ...
Achim Langenbucher   +5 more
wiley   +1 more source

Comparison of anterior chamber depth measured by three different anterior segment analysis systems

open access: yesPhotodiagnosis and Photodynamic Therapy
Purpose: This study aims to compare and evaluate the correlation and agreement among three distinct anterior segment analysis systems in measuring anterior chamber depth (ACD) in healthy myopic individuals.
Han Song   +3 more
doaj   +1 more source

Comparison of Astigmatism Prediction Accuracy for Toric Lens Implantation from Two Swept-Source Optical Coherence Tomography Devices

open access: yesClinical Ophthalmology, 2022
Robert F Melendez,1,2 Gerard Smits,3 Thao Nguyen,1 Chaselyn D Ruffaner-Hanson,1 Danielle Ortiz,2 Brad Hall4 1Juliette Eye Institute, Albuquerque, NM, USA; 2University of New Mexico School of Medicine, Department of Ophthalmology, Albuquerque, NM, USA ...
Melendez RF   +5 more
doaj  

Predictive Correction Model for Corneal Back Surface Astigmatism With IOLMaster700 Keratometry Data in a Cataractous Population

open access: yesClinical &Experimental Ophthalmology, Volume 54, Issue 1, Page 21-32, January/February 2026.
ABSTRACT Background To develop and validate various models to predict total keratometry (TK) power vector components TKC0 and TKC45 from classical keratometry (K) KC0 and KC45 based on a large dataset of pre cataract surgery IOLMaster 700 measurements.
Achim Langenbucher   +10 more
wiley   +1 more source

Reliability of a New Swept-Source Optical Coherence Tomography Biometer in Healthy Children, Adults, and Cataract Patients

open access: yesJournal of Ophthalmology, 2020
Purpose. To comprehensively assess the reliability of a new optical biometer (IOLMaster 700), based on swept-source optical coherence tomography (SS-OCT) and comparison with a standard biometer (IOLMaster 500), in healthy children, adults, and cataract ...
Jinhai Huang   +7 more
doaj   +1 more source

Blue Light Defocus Induces A Positive Effect on Refractive Status and Ocular Health: A Randomized Crossover Trial

open access: yesGlobal Challenges, Volume 9, Issue 12, December 2025.
This graphical abstract illustrates that varying degrees of intensity of defocus are associated with choroidal thickness, myopic defocus shift, and manifestations of visual fatigue, along with alterations in accommodation and convergence functions. Preliminary evidence suggests that blue light defocus technology could serve as a potential intervention ...
Jinfang Wu   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy