Results 101 to 110 of about 3,034,423 (298)
2D Skeletal Muscle Thin Film Actuators Enhance Efficiency of Biohybrid Robots
2D skeletal muscle thin film actuators generate millinewton‐scale forces and millimeter‐scale strokes while remaining functional for over 30 days. Their force density is 20‐fold higher than 3D skeletal muscle actuators, enabling multi‐fin robots with tunable speed and multidirectional steering.
Maheera Bawa +5 more
wiley +1 more source
In this research Multi-walled carbon nanotube (MWCNT) surface was modified chemically by a couple of reactions between trimethoxysilyl-propyl-amine (TMSPA) and (2)-hydroxybenzaldehyde (2-HBA) which is then characterized by FT-IR technique.
Mina Behfar +2 more
doaj +1 more source
Liquid-membrane ion-selective electrode using nicotinate
Three ion-selective electrodes for nicotinic acid are described. A solid-membrane electrode with Cu nicotinate as sensor had a linear concn. range of 5 × 10-4-5 × 10-2M, a response time 10-2M nicotinate.
G. De Angelis +5 more
core +1 more source
A trimodal anode architecture spatially regulates silicon clusters within confined interstitial environments formed by graphite and contorted hexabenzocoronene. This confinement suppresses silicon aggregation and localized stress while enabling efficient Li‐ion transport, achieving high‐capacity, stable lithium‐ion batteries.
Jeongmi Joo +11 more
wiley +1 more source
A highly selective neodymium(III) ion-selective membrane electrode has been fabricated in a poly(vinyl chloride) matrix based on 1,2-dimaleimidobenzene (DMB) as an ionophore, dibutyl phthalate (DBP) as a plasticizer, oleic acid (OA) and sodium ...
Hassan Ali Zamani, Sara Sahebnasagh
doaj +1 more source
Construction of liquid membrane type histamine ion-selective electrode. [PDF]
Construction of a liquid membrane type ion-selective electrode sensitive to divalent histaminium cation and its application to potentiometric titration are described.
工藤, 恵 +5 more
core +1 more source
An integrated pulmonary mRNA delivery platform combining novel biodegradable syringic acid‐derived ionizable lipids, design‐of‐experiments formulation optimization, and vibrating‐mesh nebulizer engineering enabled stable aerosolization and efficient lung delivery.
Neha Kaushal +21 more
wiley +1 more source
Selective Thallium (I) Ion Sensor Based on Functionalised ZnO Nanorods
Well controlled in length and highly aligned ZnO nanorods were grown on the gold-coated glass substrate by hydrothermal growth method. ZnO nanorods were functionalised with selective thallium (I) ion ionophore dibenzyldiaza-18-crown-6 (DBzDA18C6).
Z. H. Ibupoto +3 more
doaj +1 more source
A Heterogeneous Precipitate based Ion Selective Electrode for Calcium
Electrochemical Sensor Laboratory, Department of Chemistry, University of Allahabad. Allahabad-211 002 Manuscript received 21 April 1995. revised 19 February 1996.
M. C. CHATTOPADHYAYA, R. C. MISRA
core +1 more source
Electrically Induced Phase Transition and Synaptic Functionality in MoTe2/Graphene Memristors
An electrically induced reversible 2H ↔ 1T′ phase transition is demonstrated in a vertical Au/Ti/MoTe2/graphene memristor with a laterally contacted graphene electrode. Resistive switching proceeds through a compositionally invariant amorphous/2H ↔ amorphous/1T′ transformation, in which a self‐formed amorphous MoTe2 interfacial region is proposed to ...
Chien‐Hua Wang +7 more
wiley +1 more source

