Potentiometric Determination of Imatinib under Batch and Flow Injection Analysis Conditions
A new potentiometric electrochemical sensor (ion-selective electrode) based on the formation of ion associate of Imatinib mesylate with sodium tetraphenyl borate in polyvinyl chloride plactisized with dioctylphythalate was developed .Such electrode was ...
Shereen E. Abdel Karim +2 more
doaj +1 more source
A New Planar Potentiometric Sensor for In Situ Measurements
A new construction of a potentiometric sensor was introduced for the first time. It relies on the use of two membranes instead of one, as in the well-known coated-disc electrode.
Nikola Lenar +2 more
doaj +1 more source
A highly selective neodymium(III) ion-selective membrane electrode has been fabricated in a poly(vinyl chloride) matrix based on 1,2-dimaleimidobenzene (DMB) as an ionophore, dibutyl phthalate (DBP) as a plasticizer, oleic acid (OA) and sodium ...
Hassan Ali Zamani, Sara Sahebnasagh
doaj +1 more source
Possible improvement of the performance characteristics, reliability and selectivity of solid-contact nitrate ion-selective electrodes (ISE) (SC/NO3−-ISE) is attained by the application of a nitron-nitrate (Nit+/NO3−) ion association complex and ...
S. Hassan +5 more
semanticscholar +1 more source
There is considerable interest in wearable potentiometric ion sensors that can provide information about the quality of a person's health by monitoring ion concentration levels in biofluids.
Qingbo An +9 more
doaj +1 more source
A Selective Iodide Ion Sensor Electrode Based on Functionalized ZnO Nanotubes
In this research work, ZnO nanotubes were fabricated on a gold coated glass substrate through chemical etching by the aqueous chemical growth method. For the first time a nanostructure-based iodide ion selective electrode was developed. The ZnO nanotubes
Magnus Willander +2 more
doaj +1 more source
Capacitive deionization(CDI) has emerged as a promising approach to address the escalating global freshwater scarcity due to its low energy consumption and environmentally benign nature. In recent years, CDI technology has experienced rapid advancements,
CHEN Junjie +6 more
doaj +1 more source
Development of An Immobilized Enzyme Electrode for the Determination of Sulfite Ion [PDF]
An enzyme electrode was developed using the enzyme sulfite oxidase (EC1.8.3.1) immobilized onto pig intestine. Hydrogen peroxide produced was monitored amperometrically.
M.A. NabiRahni
doaj
Impact of Bicarbonate Interference on Routine Ion-Selective Electrode Chloride Measurements. [PDF]
Monteyne T +5 more
europepmc +1 more source
Development of a LoRaWAN IoT Node with Ion-Selective Electrode Soil Nitrate Sensors for Precision Agriculture. [PDF]
Bristow N +4 more