We develop a data‐driven method to derive the mathematical expressions of the Flory–Huggins interaction parameter χ for the swelling behavior of temperature–responsive hydrogels. Starting from initial assumptions of χ, our workflow combines Bayesian optimization, Flory–Rehner theory, and symbolic regression to generate candidate χ expressions.
Yawen Wang +2 more
wiley +1 more source
The impact of various calcium ion sources on the curing efficacy of MICP. [PDF]
Tao H, Jiang P, Qu J, Huang Y.
europepmc +1 more source
The temperature dependence of fatigue behavior in nickel‐based superalloys is investigated through high‐resolution measurements of plastic localization. While increasing temperature reduces localization and enhances fatigue performance in René 88DT, Inconel 718 exhibits a sharp degradation at intermediate temperature due to intensified slip ...
M. Calvat +5 more
wiley +1 more source
Flexible Integration of Alternative Energy Sources for Autonomous Sensing
Recent developments in energy harvesting and autonomous sensing mean that it is now possible to power sensors solely from energy harvested from the environment. Clearly this is dependent on sufficient environmental energy being present.
Weddell, Alex S. +3 more
core
Nanopore ion sources deliver individual ions of amino acids and peptides directly into high vacuum. [PDF]
Drachman N +5 more
europepmc +1 more source
Enhanced Physicochemical and Biological Properties of Ion-Implanted Titanium Using Electron Cyclotron Resonance Ion Sources. [PDF]
Hegedűs C +4 more
europepmc +1 more source
Fatigue Crack Initiation and Growth in Nanocrystalline Ni at Multiple Length‐Scales
Overview of miniaturized in situ SEM fatigue setup and resultant fatigue crack growth data for nanocrystalline Ni. The presented study focuses on the analysis of fatigue crack growth rate (FCGR) in focused ion beam‐notched microcantilevers prepared from nanocrystalline (NC) Ni as a model material.
Igor Moravcik +7 more
wiley +1 more source
Laser Printer Printed Ion Sources for Ambient Ionization Mass Spectrometric Analysis of Volatiles and Semivolatiles. [PDF]
Chiu CP, Chen YC.
europepmc +1 more source
Tailoring Functional Properties of Ti–Ni–Cu Shape Memory Alloy Thin Films for MEMS Actuators
A comprehensive study of critical parameters required to develop well‐performing Ti–Ni–Cu thin film shape memory alloy microactuators is provided. Materials science and device integration aspects are integrated by addressing structural and physical relationships using complementary characterization techniques as well as a practical fabrication solution
Elaheh Akbarnejad +6 more
wiley +1 more source
High-Performance, Low-Cost, Additively Manufactured Electrospray Ion Sources for Mass Spectrometry. [PDF]
Kachkine A, Velásquez-García LF.
europepmc +1 more source

