Trueness and scanning time of complete‐arch intraoral scans of edentulous arches with implants under different moisture conditions: Effects of splinting‐aid, scan body height, and scanner

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose This in vitro study evaluated the influence of the presence of saliva in varying levels on the trueness and scanning time of complete‐arch intraoral scans for implant‐supported prostheses, considering different scan body heights, splinting protocols, and scanners.
Cecília Santos Galvão   +5 more
wiley   +1 more source

Effects of scanner type and prosthesis design–luting protocol combinations on the passive fit of interim implant‐supported complete‐arch fixed dental prostheses

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To evaluate the effects of scanner type and prosthesis design–luting protocol combinations on the passive fit of interim implant‐supported complete‐arch fixed dental prostheses (ISCFDPs) fabricated using a non‐calibrated splinting grammetry system (OptiSplint).
Daizo Ishiguro   +3 more
wiley   +1 more source

3D assessment of the marginal and internal gap and fracture load of ceramic surveyed inlays designed for removable partial denture support: An in vitro comparative study

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To assess the internal and marginal gaps and the fracture load of different machinable ceramics for an inlay acting as a support for a removable partial denture. Materials and Methods Sixty extracted human teeth (first maxillary premolar) were collected (n = 10 for each group).
Mohammed M. Gad   +11 more
wiley   +1 more source

The silent zone of paediatric asthma: integrating small airway dysfunction assessment into clinical practice. [PDF]

open access: yesEClinicalMedicine
Indolfi C   +5 more
europepmc   +1 more source

Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan‐body for full‐arch implants

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To compare the relative accuracy of intraoral photogrammetry (IPG) and intraoral scan (IOS) with conventional scan bodies (IOS‐CB) for complete‐arch implant impressions, using the conventional splinted open‐tray impression digitized with a laboratory scanner (COT‐LS) as the reference standard.
Sherif Aly Sadek   +3 more
wiley   +1 more source

Accuracy of complete‐arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry

open access: yesJournal of Prosthodontics, EarlyView.
ABSTRACT Purpose The purpose of this in vitro study was to compare the accuracy of analog impressions, intraoral scanning, extraoral photogrammetry, and intraoral photogrammetry in recording complete‐arch implant positions. Materials and Methods A stainless‐steel reference model representing an edentulous maxilla with six parallel implants and ...
Richard Lee   +2 more
wiley   +1 more source

Digital era in oral rehabilitation: a scoping review of trends and implications for clinical practice. [PDF]

open access: yesBraz Oral Res
Carreiro ADFP   +9 more