Results 61 to 70 of about 201 (112)
Qualitative and quantitative tests for iothalamic acid
Donald E. Cadwallader
openaire +2 more sources
[125I]iothalamic acid clearance is used for the estimation of glomerular filtration rate. Therefore, we developed a coupled-column liquid chromatography for the simultaneous determination of iothalamic acid and creatinine in human serum and urine samples to calculate their clearance.
T, Seki +5 more
openaire +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Biopharmaceutics & Drug Disposition, 1986
AbstractThe oral absorption of iothalamate and the effect of amino acids on its absorption were studied in 6 dogs and 6 rats using a simple HPLC assay. The results showed that iothalamate was absorbed in dogs, averaging 9·9, 8·5, and 10·0 per cent following the administration of 40 and 100mg kg−1 of iothalamic acid capsules and 50mg kg−1 of sodium ...
T, Prueksaritanont +3 more
openaire +2 more sources
AbstractThe oral absorption of iothalamate and the effect of amino acids on its absorption were studied in 6 dogs and 6 rats using a simple HPLC assay. The results showed that iothalamate was absorbed in dogs, averaging 9·9, 8·5, and 10·0 per cent following the administration of 40 and 100mg kg−1 of iothalamic acid capsules and 50mg kg−1 of sodium ...
T, Prueksaritanont +3 more
openaire +2 more sources
Journal of Chromatography B: Biomedical Sciences and Applications, 1998
A sensitive and specific high-performance liquid chromatographic assay was developed for the simultaneous determination of p-aminohippuric acid (PAH), acetyl-p-aminohippuric acid (aPAH), and iothalamate in human plasma and urine. Plasma samples were prepared by protein precipitation with acetonitrile followed by evaporation, reconstitution in mobile ...
T C, Dowling, R F, Frye, M A, Zemaitis
openaire +2 more sources
A sensitive and specific high-performance liquid chromatographic assay was developed for the simultaneous determination of p-aminohippuric acid (PAH), acetyl-p-aminohippuric acid (aPAH), and iothalamate in human plasma and urine. Plasma samples were prepared by protein precipitation with acetonitrile followed by evaporation, reconstitution in mobile ...
T C, Dowling, R F, Frye, M A, Zemaitis
openaire +2 more sources
Journal of Chromatography B: Biomedical Sciences and Applications, 1984
A simple, rapid and micro high-performance liquid chromatographic method was developed for separate or simultaneous determination of p-aminohippuric acid and iothalamate in plasma and urine using p-aminobenzoic acid as an internal standard. The method involved deproteinizing samples with two volumes of acetonitrile followed by injection of 5 ...
T, Prueksaritanont +2 more
openaire +2 more sources
A simple, rapid and micro high-performance liquid chromatographic method was developed for separate or simultaneous determination of p-aminohippuric acid and iothalamate in plasma and urine using p-aminobenzoic acid as an internal standard. The method involved deproteinizing samples with two volumes of acetonitrile followed by injection of 5 ...
T, Prueksaritanont +2 more
openaire +2 more sources
American Journal of Kidney Diseases, 1992
Traditionally, creatinine clearance is used as an estimation of the glomerular filtration rate (GFR) because of its relative ease and low cost. Errors in collection limit its usefulness. Estimation of GFR using 99m Tc diethylene-triamine pentaacetic acid (Tc-DTPA) by direct scintigraphic determination of fractional radionuclide accumulation within ...
Roger A. Rodby +3 more
openaire +1 more source
Traditionally, creatinine clearance is used as an estimation of the glomerular filtration rate (GFR) because of its relative ease and low cost. Errors in collection limit its usefulness. Estimation of GFR using 99m Tc diethylene-triamine pentaacetic acid (Tc-DTPA) by direct scintigraphic determination of fractional radionuclide accumulation within ...
Roger A. Rodby +3 more
openaire +1 more source
Journal of Chromatography B: Biomedical Sciences and Applications, 2000
A high-performance liquid chromatography method applied to determine p-aminohippuric acid (PAH) and iothalamate (IOT) in serum and urine samples of patients was evaluated according to recovery, reproducibility and linearity utilizing narrow-bore columns.
T, Kos +5 more
openaire +2 more sources
A high-performance liquid chromatography method applied to determine p-aminohippuric acid (PAH) and iothalamate (IOT) in serum and urine samples of patients was evaluated according to recovery, reproducibility and linearity utilizing narrow-bore columns.
T, Kos +5 more
openaire +2 more sources
Journal of Chromatography B, 2005
A simple high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of iohexol, iothalamate, p-aminohippuric acid (PAH) and n-acetyl-p-aminohippuric acid (n-acetyl-PAH) in human plasma and urine. A C(18) column at a flow rate of 1 ml/min with an aqueous mobile phase of trifluoroacetic acid (0.1% TFA in ...
Don, Farthing +7 more
openaire +2 more sources
A simple high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of iohexol, iothalamate, p-aminohippuric acid (PAH) and n-acetyl-p-aminohippuric acid (n-acetyl-PAH) in human plasma and urine. A C(18) column at a flow rate of 1 ml/min with an aqueous mobile phase of trifluoroacetic acid (0.1% TFA in ...
Don, Farthing +7 more
openaire +2 more sources