Left Ventricular wall Thickness and Decrement Evoked Potentials in Ablation of Ischemic Ventricular Tachycardia

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Introduction Preprocedural imaging can improve the success rate of ventricular tachycardia (VT) ablation. Left ventricular wall thickness (LVWT) measured by cardiac computed tomography (CT) can be used to identify infarct regions. We sought to determine whether an association exists between left ventricular wall thickness (LVWT) as obtained ...
Alwin B. P. Noordman   +4 more
wiley   +1 more source

Left Bundle Branch Area Pacing Reverts Electromechanical Window Negativity to a Similar Extent as Biventricular Pacing

open access: yesPacing and Clinical Electrophysiology, EarlyView.
BiVP = biventricular pacing; CRT = cardiac resynchronization therapy; EMW = electromechanical window; LBBAP = left bundle branch area pacing; QAoC = Time interval from the onset of the QRS complex to the center of the aortic valve closure artifact; QT = QT interval measured by tangent method.
Florien Klein   +18 more
wiley   +1 more source

Long‐Term Cardiovascular Outcomes Following New‐Onset Arrhythmias During Pregnancy

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background Arrhythmias during pregnancy are increasingly prevalent and associated with acute adverse cardiovascular outcomes, yet their long‐term cardiovascular implications remain poorly defined. To address this gap, we conducted a large population‐based study to evaluate 5‐year cardiovascular outcomes following incident arrhythmias during ...
Sanya Dhama   +4 more
wiley   +1 more source

Safety and Performance of INVICTA DF4 Ventricular Defibrillation Lead: Results From APOLLO Prospective Multicenter Study

open access: yesPacing and Clinical Electrophysiology, EarlyView.
Abstract Background Implantable cardioverter‐defibrillator (ICD) therapy relies on reliable right ventricular leads for pacing, sensing, and defibrillation. The INVICTA DF4 lead is an active‐fixation, quadripolar design intended to optimize implant workflow and long‐term safety and performance. Methods APOLLO was a prospective, multicenter, single‐arm,
Klaus K. Witte   +13 more
wiley   +1 more source

Extracellular matrix alterations in chronic ischemic cardiomyopathy revealed by quantitative proteomics. [PDF]

open access: yesJCI Insight
Buck KM   +11 more
europepmc   +1 more source

Hypertrophic cardiomyopathy in the young: Another form of ischemic cardiomyopathy?

open access: yesJournal of the American College of Cardiology, 1993
Botvinick, Elias H.   +3 more
openaire   +2 more sources