Results 121 to 130 of about 9,184,490 (148)
7-Year Efficacy and Safety of iStent Inject Trabecular Micro-Bypass in Combined and Standalone Usage
Introduction!#!This study evaluated 7-year effectiveness and safety of second-generation trabecular micro-bypass implantation (iStent inject) either in combination with cataract surgery or as a standalone procedure (Combined or Standalone subgroups ...
Gerd U. Auffarth, Fritz H Hengerer
exaly +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
ISTENT INJECT W AND KAHOOK DUAL BLADE FOR TREATING MILD-TO-MODERATE GLAUCOMA.
Georgian medical news, 2023This is a review article to contrast the lowering effect of intraocular pressure of two minimally invasive glaucoma surgery (MIGS) devices namely iStent inject (the second edition) versus excisional goniotomy using Kahook dual blade (KDB) as a combo procedure with cataract surgery, as well as post-operative best corrected visual acuity BCVA loss for ...
openaire +1 more source
2 Year results of combined phacoemulsification‐
Aims/Purpose: Our aim is to review the 2 year results of combined phacoemulsification and iStent inject W implantation in a single centre in East London.Methods: Patients were listed for surgery when cataract surgery was needed and further control of glaucoma was necessary.
Kleonikos Tsakiris +2 more
openaire +1 more source
Archivos de la Sociedad Española de Oftalmología (English Edition)
To evaluate intraocular pressure (IOP) and the number of hypotensive medications in patients with mild-to-moderate appositional primary angle-closure glaucoma (PACG) after phacoemulsification surgery (phaco-only group) versus phacoemulsification combined with the implantation of two iStent® W inject trabecular stents (Glaukos Corporation, CA, USA ...
M. Cerdá Ibáñez +4 more
openaire +2 more sources
To evaluate intraocular pressure (IOP) and the number of hypotensive medications in patients with mild-to-moderate appositional primary angle-closure glaucoma (PACG) after phacoemulsification surgery (phaco-only group) versus phacoemulsification combined with the implantation of two iStent® W inject trabecular stents (Glaukos Corporation, CA, USA ...
M. Cerdá Ibáñez +4 more
openaire +2 more sources
White crescent sign in iStent inject® W implantation using the Swan-Jacob gonioscopy lens
Archivos de la Sociedad Española de Oftalmología (English Edition)To describe the value of the "white crescent sign" as a gonioscopic reference for accurate implantation of the iStent W device. The ab interno surgical technique using the Swan-Jacob direct gonioscopy lens is described. Optical principles of coaxial visualization and the effects of peripheral aberrations and parallax in minimally invasive glaucoma ...
openaire +2 more sources
Real-World Outcomes Of Standalone Istent Inject W Implantation: 12-Month Results
2023Federico Merlin +2 more
openaire +1 more source

