Results 41 to 50 of about 9,184,490 (148)
Colin Clement,1– 4 Frank Howes,5 Alexandros Ioannidis,6 Michael Shiu,7 David Manning,8 Jed A Lusthaus,3,4,9 Simon E Skalicky,10 Todd W Goodwin11 1Eye Associates, Sydney, NSW, Australia; 2Fairfield Eye Surgery, Fairfield, NSW, Australia; 3Glaucoma Unit ...
Clement C +7 more
doaj
iStent® Trabecular Microbypass Stent: An Update
Due to the high rates of complications and failure experienced with current glaucoma procedures, there is a continuous search for a safer and more effective glaucoma surgery. A new class of procedures termed minimally invasive glaucoma surgeries (MIGS) aim to fill this void by offering an alternative method of IOP reduction associated with markedly ...
Arthur Fernandes Resende +4 more
wiley +1 more source
Innovative Drug Delivery Systems for the Treatment of Glaucoma
This review aims to provide a comprehensive overview of current topical drug delivery strategies for ocular hypotensive agents in glaucoma therapy. Additionally, it discusses the potential impact of emerging nanotechnological and biomaterial‐based systems in shaping the future of ophthalmic drug delivery, with an emphasis on enhancing efficacy, safety,
Jing Chu +9 more
wiley +1 more source
Abstract Purpose This study assesses the PAUL® glaucoma implant (PGI) in primary open angle glaucoma (POAG) and pseudoexfoliative glaucoma (PEXG) after failed glaucoma surgery. Given PEXG's more aggressive nature, limited research exists on PGI outcomes in this subgroup. This study aims to compare PGI's efficacy and safety in both conditions. Methods A
Constance Liegl +8 more
wiley +1 more source
Supplemental material, sj-docx-1-ejo-10.1177_11206721231190417 for Novel surgical technique to manage iStent inject over-implantation by Bryan Chin Hou Ang and Elizabeth Jiahui Chen in European Journal of ...
Bryan Chin Hou Ang (9278408) +1 more
core +1 more source
Louis Cantor,1 Dan Lindfield,2 Federico Ghinelli,3 Anna W Świder,3 Francesca Torelli,3 Carolyn Steeds,3 Jaime E Dickerson Jr,4,5 Dan Q Nguyen6 1Eugene and Marilyn Glick Eye Institute, Indiana School of Medicine, Indianapolis, IN, USA; 2Royal ...
Cantor L +7 more
doaj
Purpose To evaluate the safety and efficacy of infrared (IR) illumination using a digital microscope platform to perform uncomplicated cataract surgery. Methods A retrospective case series of 39 eyes (33 patients) that underwent cataract surgery under topical anesthesia.
Brady Wortz +5 more
wiley +1 more source
A 41‐year‐old female presented with persistent diarrhea, and was diagnosed with Zollinger‐Ellison syndrome when her gastrin level was greater than 3000 ng/L. All modalities for preoperative localization of her gastrinoma were unsuccessful, including transabdominal and endoscopic ultrasound, computed tomography, pancreatic angiogram, selective ...
Humera Ali +3 more
wiley +1 more source
Comparison of temporal versus nasal positioning of iStent Inject W®
The goal of the present study was to compare the effect of nasal versus temporal placement of the iStent Inject W® during phacoemulsification on intraocular pressure (IOP).Over 5 consecutive years, 389 eyes of 244 patients undergoing phacoemulsification with 2 iStent Inject W® injections in a tertiary referral center were included retrospectively.
Vermot-Desroches, V. +11 more
openaire +3 more sources
Association Between Prior Selective Laser Trabeculoplasty and Phaco‐iStent Inject Efficacy
ABSTRACT Background To evaluate the association between prior selective laser trabeculoplasty (SLT) on intraocular pressure (IOP) lowering efficacy of phacoemulsification combined with iStent inject (phaco‐iStent). Methods Retrospective study of 1550 eyes of 1023 patients with and without prior SLT that underwent phaco‐iStent.
Jeremy C. K. Tan +8 more
wiley +1 more source

