Results 71 to 80 of about 9,184,490 (148)

Abstracts of the 13th Annual Meeting of Israel Society for Neuroscience

open access: yes, 2005
Neural Plasticity, Volume 12, Issue 1, Page 1-68, 2005.
wiley   +1 more source

Efficacy and safety of ELIOS excimer laser trabeculostomy versus iStent inject as an adjunct to phacoemulsification: a retrospective comparative study

open access: yes
Background/aims Minimally invasive glaucoma surgery (MIGS) procedures are commonly combined with phacoemulsification to provide additional intraocular pressure (IOP) and/or topical medication reduction in patients
Keith R Martin   +13 more
core   +1 more source

A prospective analysis of iStent inject microstent positioning

open access: yes, 2019
Precis: A larger proportion of iStent inject microstents than suggested by gonioscopic examination could be entirely burrowed within the trabeculum (45.7%).
Gillmann, Kevin   +3 more
core   +1 more source

Two-Year Post-Market Surveillance of iStent inject® W Combined with Phacoemulsification in Japanese Open-Angle Glaucoma Eyes

open access: yesClinical Ophthalmology
Masaru Inatani,1 Ichiro Kohama,2 Alice Chu3 1Department of Ophthalmology, Faculty of Medical Sciences, University of Fukui, Fukui, Japan; 2Department of Clinical Affairs, Glaukos Japan, Tokyo, Japan; 3Department of Market Access and Medical Affairs ...
Inatani M, Kohama I, Chu A
doaj  

Micro-invasive glaucoma surgery (MIGS): a review of surgical procedures using stents [Corrigendum]

open access: yes, 2018
Pillunat LE, Erb C, Jünemann AGM, et al. Clinical Ophthalmology. 2017;11:1583–1600.Throughout the paper iStent inject® was incorrectly listed as iStent inject or iStent® inject.
Jünemann AGM   +3 more
core  

Prospective unmasked randomized evaluation of the iStent inject® versus two ocular hypotensive agents in patients with primary open-angle glaucoma

open access: yes, 2014
Antonio M Fea,1 Jose I Belda,2 Marek Rękas,3 Anselm Jünemann,4 Lydia Chang,5 Luis Pablo,6 Lilit Voskanyan,7 L Jay Katz81Università degli Studi di Torino, Clinica Oculistica, Torino, Italy; 2Hospital Torrevieja Salud, UTE, Servicio de ...
Pablo L   +7 more
core  

Complications.

open access: yes
PurposeThe study aimed to compare the 12-month post-operative outcomes of iStent and iStent inject W (inject W), and the factors associated with their success in open-angle glaucoma.MethodsThis single-center, retrospective comparative case series ...
Yoshihito Sakanishi (17904254)   +4 more
core   +1 more source

Effect of iStent inject on unmedicated intraocular pressure in glaucoma: exploratory analysis of clinical trial data

open access: yes
Purpose The direct effect of iStent inject on intraocular pressure (IOP) in patients with glaucoma is difficult to quantify in pragmatic trials where rates of post-surgical IOP-lowering therapy differ between intervention groups.
Zhengyang Liu   +6 more
core   +1 more source

Evaluación de la posición del implante iStent inject® mediante gonioscopía y su correlación con la presión intraocular [PDF]

open access: yes
Se realizó un estudio clínico observacional descriptivo de tipo transversal de una serie de pacientes diagnosticados de glaucoma intervenidos con iStent inject en el Servicio de Oftalmología del HURH de Valladolid entre los años 2019 y 2023, a quienes
López Rojas, Carolina
core  

Combined cataract surgery with iStent inject® implantation compared to cataract surgery alone in patients with open-angle glaucom

open access: yes
Diese Studie vergleicht den Augeninnendruck (IOD) und Medikamentenbedarf nach alleiniger Kataraktoperation versus Kombination mit iStent inject® bei Offenwinkelglaukom. 150 Augen wurden retrospektiv analysiert.
Gurbanzade, Shakhriiar
core  