Precision (Repeatability and Reproducibility) and Agreement of Corneal Power Measurements Obtained by Topcon KR-1W and iTrace [PDF]

open access: yesPLoS ONE, 2016
PURPOSE:To evaluate the repeatability and reproducibility of corneal power measurements obtained by Topcon KR-1W and iTrace, and assess the agreement with measurements obtained by Allegro Topolyzer and IOLMaster.
Yanjun Hua, Qiang Wu
exaly   +3 more sources

Repositioning of Vertical Implantable Phakic Contact Lens [PDF]

open access: yesClinical Case Reports, Volume 14, Issue 9, September 2026.
Vertical orientation of Implantable Phakic Contact Lens. ABSTRACT Implantable phakic contact lens (IPCL) V2.0 has a special patterned hole on the leading left corner to ensure correct orientation and positioning. Incorrect orientation is an absolute indication for repositioning.
Sushank Bhalerao   +4 more
wiley   +2 more sources

Accuracy of Toric Intraocular Lens Implantation Using Three‐Random‐Point Marking Method: A Prospective Pilot Study [PDF]

open access: yesJournal of Ophthalmology, Volume 2026, Issue 1, 2026.
Introduction This study aimed to compare the accuracy of three‐random‐point (TRP) marking method with the slit‐lamp horizontal meridian (SHM) marking method by using an image‐guided system in the positioning of a toric intraocular lens (IOL). Materials and Methods A total of 60 eyes of 54 patients who underwent cataract surgery were prospectively ...
Shuilian Chen   +5 more
wiley   +2 more sources

Clinical evaluation of toric intraocular lens implantation based on iTrace wavefront keratometric astigmatism

open access: yesBMC Ophthalmology, 2020
Background Currently, there is no standard technique for determining corneal astigmatism. The iTrace wavefront aberrometry of cornea calculated steep power and axis based on the best Zernike mathematical fit from all topo data within 4 mm circle.
Zhe Zhang   +4 more
exaly   +3 more sources

Wavefront Automated Refraction Comparison of Three Different IOLs: Aspheric Monofocal and Two Enhanced Monofocal IOLs [PDF]

open access: yesVision
The objective of this study was to compare subjective manifest refraction with wavefront-based automated refraction using iTrace (ray tracing) and LadarWave (Hartmann–Shack) in eyes implanted with two enhanced monofocal intraocular lenses (IOLs) and a ...
Arthur Buffara van den Berg   +6 more
doaj   +2 more sources

Panoptix versus AT Lisa: comparing stability of two trifocal intraocular lenses with different haptic designs using the iTrace system [PDF]

open access: yesBMC Ophthalmology
Background The objective of this study was to compare the rotational stability of C-haptic PanOptix Toric (Alcon) and plate haptic AT Lisa Toric (Carl Zeiss Meditec) intraocular lenses (IOLs) using the iTrace system.
Dilek Yasa   +5 more
doaj   +2 more sources

Alpha and Kappa angle on postoperative visual quality in cataract surgery [PDF]

open access: yesInternational Journal of Ophthalmology
AIM: To explore the effect of Alpha angle and Kappa angle before multifocal intraocular lenses (MIOLs) implantation on postoperative visual quality of patients.
Xiao-Na Chen   +4 more
doaj   +2 more sources

Distribution of Angle Alpha in a Large Population in Eastern China: An Analysis of the 30705 Eyes Using the Ray Tracing Aberrometer [PDF]

open access: yesClinical Ophthalmology
Zhixiang Hua,1– 5,* Qiulin Zeng,6,* Limei Zhang,7 Jiying Shen,7,* Jin Yang1– 5,* 1Department of Ophthalmology and the Eye Institute, Eye and Ear, Nose, and Throat Hospital, Fudan University, Shanghai, People’s Republic of China; 2The Key ...
Hua Z, Zeng Q, Zhang L, Shen J, Yang J
doaj   +2 more sources

iTrace – A Ray Tracing Aberrometer

open access: yesDelhi Journal of Ophthalmology, 2019
Modern ophthalmology focusses on visual quality and not just visual acuity. The quality of vision is affected by both lower and higher order aberrations.
Pranita Sahay   +2 more
exaly   +3 more sources

Study of Visual Quality and Higher Order Aberrations in Early Posterior Capsular Opacification [PDF]

open access: yesJournal of Ophthalmology, Volume 2025, Issue 1, 2025.
Purpose: This study aims to explore the visual quality and characteristics of higher order aberrations (HOAs) in patients with early posterior capsule opacification (PCO), providing a theoretical basis for the clinical assessment of early PCO and the potential benefits of Nd:YAG posterior capsulotomy.
Zhangyi Li   +5 more
wiley   +2 more sources