Results 61 to 70 of about 6,570 (105)
Department Of Nuclear EngineeringIn the light water reactors, a number of safety systems have been installed to prevent the progression of the accidents and return to the safety condition.
Park, Seong Dae
core
External Reactor Vessel Cooling Evaluation for Severe Accident Mitigation in NPP Krško
The In-Vessel corium Retention (IVR) through the External Reactor Vessel Cooling (ERVC) is mean for maintaining the reactor vessel integrity during a severe accident, by cooling and retaining the molten material inside the reactor vessel. By doing this,
Bruno Glaser +5 more
core
Visual Interactive Voice Response (Visual IVR)
Relatório de Estágio do Mestrado em Engenharia Informática apresentado à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.Since the late 1990’s, companies started to introduce interactive voice response (IVR) systems in their call centers ...
Calvo, Marcos André Ferreira
core
IVR: Its Coherent and Incoherent Dynamics
In this paper, we discuss the dynamics of intramolecular vibrational-energy redistribution (IVR) in two limits: the coherent and incoherent limits. These descriptions are introduced to account for experiments done in time and frequency domains.
Zewail, Ahmed H.
core
OUTBOUND IVR - AUTOMATIC CALLING SYSTEM
V diplomskem delu smo spoznali vzpostavitev in razvoj samodejnega klicnega sistema s pomočjo računalniške hišne telefonske centrale Asterisk in medijske platforme Voxeo Prophecy.
Novak, Gregor
core
The use of traditional IVR (Interactive Voice Response) methods often proves insufficient to meet customer needs. This article examines the application of artificial intelligence (AI) technologies to enhance the efficiency of IVR systems in call centers.
Kosherbay, Gassyrbek, Apbaz, Nurgissa
core
Erfurt, Univ., Jur. Diss., 1786Qvas ... Pvblicae Disqvisitioni D. XXX. Mart. MDCCLXXXVI. Svbiicit Petrvs Franc. Agricola ... Respondente Domino Christiano Gotthard, Ivr.
Agricola, Peter Franz +1 more
core
Counter-Bias by Design : Sequencing × Accountability in Voice-First IVR
Goal: Test whether small choice-architecture nudges in a voice-first IVR preserve user agency. Design: 2×2 between-subjects — Sequencing {system-first vs human-first} × Accountability framing {“Claim” vs “Modify”}.
Akshaya Jayasankar
core
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Development of IVR-ERVC evaluation method and its application to the SMART
Annals of Nuclear Energy, 2021Abstract An IVR (In-Vessel corium Retention) through ERVC (External Reactor Vessel Cooling) is known to be an effective means for maintaining the reactor vessel integrity during severe accidents in nuclear power plants. The evaluation method of the IVR-ERVC for small reactors was developed and applied to a small integral reactor of the SMART (System ...
Rae-Joon Park +2 more
exaly +2 more sources
Feasibility of flooding the reactor cavity with liquid gallium coolant for IVR-ERVC strategy
Abstract In this paper, a new approach replacing the ERVC coolant by a liquid metal instead of water is studied to avoid the heat removal limit of CHF during boiling of water. As the flooding material, gallium is used in terms of the melting and boiling points.
Park, Seong Dae, Bang, In Cheol
openaire +3 more sources

