Results 91 to 100 of about 2,388,667 (300)
IntroductionSuitable midsoles of running shoes provide better protection for the feet. However, previous studies on the effect of midsole hardness on running biomechanics have ignored the important factor of running velocity and have not reached ...
Luming Yang +8 more
doaj +1 more source
Inter-joint coupling and joint angle synergies of human catching movements
A central question in motor control is how the central nervous system (CNS) deals with redundant degrees of freedom (DoFs) inherent in the musculoskeletal system. One way to simplify control of a redundant system is to combine several DoFs into synergies.
Bockemühl, Till +2 more
openaire +2 more sources
Electrospun Wood‐Derived Biopolymers as Electrodes in Electrochemical Energy Storage Technologies
Electrospinning transforms wood‐derived cellulose and lignin into architecturally defined, binder‐free carbon electrodes with tuneable porosity and functionality. This review shows how fibre design enables decoupled charge and mass transport, enhancing performance across battery systems, while identifying key challenges in spinnability, scalability ...
Michael W. Thielke +3 more
wiley +1 more source
Knee motion is a key biomarker in chronic musculoskeletal diseases, yet conventional in-lab optical motion capture falls short of identifying how knee motion continuously impacts joint health outside the lab.
Ke Song, Josh R. Baxter
doaj +1 more source
Coordinated Architectural and Chemical Reinforcement in the Crushing Mandible of a Soldier Termite
The crushing mandible of a soldier termite withstands substantial biting loads despite lacking mineral. Its cuticle is partitioned: convex teeth pair hardness and zinc enrichment with aligned chitin fibers for contact durability, while stiffer concave regions between teeth carry bending loads.
Andrew Tran Nguyen +16 more
wiley +1 more source
Intrepid Dynamic Exoskeletal Orthosis (IDEO), developed in Walter Reed National Military Medical Center (WRNMMC), is a custom, energy-storing orthosis made of carbon fiber.
Ji Chen +3 more
doaj +1 more source
The ankle joint angle profiles.
Ensemble average of the ankle joint angle (n = 11) during barefooted (dots) and high-heeled (triangles) walking. The ankle joint angle of each subject is a mean±SE of the ankle joint angle from 50 strides measured over 60 s of walking and used as input ...
Tine Alkjær (323061) +3 more
core +1 more source
A gradient‐engineered all‐paper sensor is fabricated by integrating MXene and in situ grown AgNPs within hierarchical cellulose networks. The device breaks the sensitivity–detection range trade‐off through cascaded conductive pathways, enabling ultrahigh pressure sensitivity, humidity–pressure decoupled dual‐mode sensing, and outstanding EMI shielding,
Ao Li +7 more
wiley +1 more source
Background/Objectives: Artificial tendons offer an alternative to biological tendon grafts and may restore normative biomechanical functions in humans and animals suffering segmental or complete tendon loss. The aim of this study was to quantify movement
Obinna P. Fidelis +6 more
doaj +1 more source

