Results 11 to 20 of about 855,316 (304)
The influence of great toe valgus on pronation and frontal plane knee motion during running [PDF]
Injury rates in running range from 19.4‐79.3%, with injuries at the knee comprising 42.1%. Pronation and altered frontal plane knee joint range of motion have been linked to such injuries.
Barry, Gill +3 more
core +2 more sources
Effect of Subcutaneous Muscle Displacement of Flexor Carpi Radialis on Surface Electromyography
Changes in joint angle can change the position and orientation of muscle fibers relative to the surface EMG electrode. Our previous study has shown that EMG patterns can identify hand/wrist movements with a greater degree of classification accuracy (CA ...
Lizhi Pan, Kai Liu, Jianmin Li
doaj +1 more source
Carry-over coarticulation in joint angles [PDF]
Coarticulation indicates a dependence of a movement segment on a preceding segment (carry-over coarticulation) or on the segment that follows (anticipatory coarticulation). Here we study coarticulation in multidegrees of freedom human arm movements. We asked participants to transport a cylinder from a starting position to a center target and on to a ...
Hansen, Eva +3 more
openaire +2 more sources
Gait-training rehabilitation machines (MGTR) are contraptions used for the motor rehabilitation of patients with movement disorders resulting from stroke and Parkinson’s disease.
Jeong-Woo Seo +4 more
doaj +1 more source
Introduction: Thoracolumbar kyphosis (TLK) is a common feature in patients with spinal deformities. However, due to limited studies, the impacts of TLK on gait have not been reported. The objective of the study was to quantify and evaluate the impacts of
Hao Cheng +9 more
doaj +1 more source
Joint angle tracking with inertial sensors
Many wearable inertial systems have been used to continuously track human movement in and outside of a laboratory. The number of sensors and the complexity of the algorithms used to measure position and orientation vary according to the clinical application. To calculate changes in orientation, researchers often integrate the angular velocity. However,
Mahmoud, El-Gohary +2 more
openaire +4 more sources
This paper describes the use of nine-axis motion sensors to evaluate knee joint angle estimation accuracy during walking. The nine-axis motion sensor comprises a three-axis gyro sensor, a three-axis acceleration sensor and a three-axis geomagnetic sensor.
Ayuko SAITO +3 more
doaj +1 more source
This paper proposes a method of estimating the knee joint angle during walking using nine-axis motion sensors in a varying magnetic field. The nine-axis motion sensor comprises a three-axis gyro sensor, a three-axis acceleration sensor, and a three-axis ...
Ayuko SAITO, Yuto NARA, Kazuto MIYAWAKI
doaj +1 more source
A trunk-twisting posture is strongly associated with physical discomfort. Measurement of joint kinematics to assess physical exposure to injuries is important.
Pin-Ling Liu +3 more
doaj +1 more source
Performance of bolted steel-beam to CFST-column joints using stiffened angles in column-removal scenario [PDF]
This paper presents three experimental investigations on the performance of steel-beam to CFST-column joints using stiffened angle, long bolts and fin plate under a middle column removal scenario. Three specimens were designed and tested.
Fu, F., Gao, S., Guo, L., Xu, M.
core +1 more source

