Results 231 to 240 of about 134,758 (315)
ABSTRACT Background and Aims Patient‐reported outcome measures (PROMs) are widely used to evaluate knee function and symptoms. WOMAC, KOOS, and OKS are commonly used knee‐specific PROMs, and their validity and reliability are well established. However, there is limited research focusing on their feasibility among older Chinese population.
Ziyang Dong +4 more
wiley +1 more source
Extended Reality in Rehabilitation Medicine: A Systematic Review
ABSTRACT Background and Aims This systematic review synthesizes current evidence on the application of extended reality (XR) technologies, comprising virtual reality (VR), augmented reality (AR), and mixed reality (MR), in rehabilitation medicine, assessing their effects across diverse rehabilitation domains and clinical outcomes.
Jie Hao, Yao Yao, Ka‐Chun Siu
wiley +1 more source
Laryngeal mask airway improves hemodynamics and reduces pharyngeal discomfort in total joint arthroplasty. [PDF]
Jiang W +9 more
europepmc +1 more source
An optimized protocol combining serum lyophilization, solid‐state alkaline digestion, and PCA‐assisted EDS analysis was validated for the analysis of UHMWPE wear debris. The method increased recovery yield by 20‐fold compared to liquid digestion and preserved particle morphology.
Luis Antonio da Costa Bento +5 more
wiley +1 more source
Is preoperative emergency department utilization associated with postoperative healthcare utilization after total joint arthroplasty? A social vulnerability index based analysis. [PDF]
Burke JF +5 more
europepmc +1 more source
ABSTRACT Indwelling medical implants are susceptible to developing biofilm‐associated infections that are notoriously difficult to eradicate. These persistent infections often cannot be resolved with antibiotics alone and typically require surgical intervention for effective management.
F. Ruben H.A. Nurmohamed +15 more
wiley +1 more source
Artificial intelligence in joint arthroplasty: A bibliometric analysis of global research trends (2001-2025). [PDF]
Peng X, Tan F, Hu Y, Pu H, Zou W, Qu C.
europepmc +1 more source
ABSTRACT This study compared the volume of acetabular bone resection between an anatomically designed cementless ceramic‐on‐ceramic hip resurfacing arthroplasty (H1HR) and metal‐on‐metal hip resurfacing (Birmingham Hip Resurfacing; BHR). We hypothesized that the anatomical design of the H1 cup would reduce the need for medialization to avoid rim ...
Yuki Yamamuro +4 more
wiley +1 more source
Unfolding the risk: a pilot study of airborne contamination in the operating room during total joint arthroplasty. [PDF]
Ibrahim DA +7 more
europepmc +1 more source
Natural history of the dysplastic hip following modern periacetabular osteotomy [PDF]
Clohisy, John C +7 more
core +1 more source

