Background Repair of the posterior soft tissue via a posterolateral approach following total hip arthroplasty has been reported to mitigate the risk of dislocation. The joint capsule serves as the primary protective barrier, and while previous techniques
Ruinan Chen +6 more
doaj +1 more source
ISOLATED BILATERAL RECURRENT DISLOCATION OF THE CALCANEOCUBOID JOINT
An 18-year-old girl with moderate joint laxity presented with recurrent dislocation of the calcaneocuboid joint in both feet. We achieved successful stabilisation on both sides by reconstruction of the ligaments and capsule using the plantaris tendons.
C. N. Mcharo, P. E. Ochsner
core +1 more source
Recent Advances of Slip Sensors for Smart Robotics
This review summarizes recent progress in robotic slip sensors across mechanical, electrical, thermal, optical, magnetic, and acoustic mechanisms, offering a comprehensive reference for the selection of slip sensors in robotic applications. In addition, current challenges and emerging trends are identified to advance the development of robust, adaptive,
Xingyu Zhang +8 more
wiley +1 more source
Chondrocyte response to in vitro mechanical injury and co-culture with joint capsule tissue [PDF]
Thesis (Ph. D.)--Massachusetts Institute of Technology, Biological Engineering Division, 2005.Includes bibliographical references.Acute traumatic joint injury in young adults leads to an increased risk for the development of osteoarthritis (OA) later in ...
Lee, Jennifer H. (Jennifer Henrica)
core
Neuroanatomical distribution of sensory receptors in the human elbow joint capsule
BackgroundThe topographic arrangement of sensory receptors in the human elbow joint capsule is pertinent to their role in the transmission of neural signals.
Maria F Deslivia +6 more
core +1 more source
We introduce an additively manufactured bioreactor with a perfusion flow system and integrated temperature and pH sensors for skeletal muscle tissue biofabrication. The bioreactor's performance was evaluated by assessing the viability, spreading of the myoblast cells in a printed scaffold, and contraction of the isolated murine musculi interossei ...
Lys Sprenger +9 more
wiley +1 more source
Here, two types of electronic components are presented: a strain sensor and a stable resistor. Electrofluids properties are tuned to match these behaviors by selecting the type of filler. We show that the morphology of the filler together with its oxygen content are the key parameters to create electrical and mechanical networks with distinct responses.
Dominik S. Schmidt +4 more
wiley +1 more source
A self‐healing and electrically conductive liquid metal elastomer enables robust self‐soldering of surface mount devices for soft electronics. Photothermally activated conductive pathways, strong pressure‐sensitive adhesion, and stable package‐integrated contacts provide high conductivity and extreme stretchability.
Su Thiri San +5 more
wiley +1 more source
Bamboo Medical Application: A State‐of‐the‐Art Review
This review presents a structured classification of bamboo's current use in healthcare. It organizes applications into medical textiles and medical devices, with further divisions based on function and level of invasiveness. It also examines material utilization based on bamboo's structural role, highlighting how it supports both protective and ...
Haymanot Beza Lamesgin +3 more
wiley +1 more source
Background: The capacity of an unrepaired joint capsule to heal after primary hip arthroscopic surgery in patients with femoroacetabular impingement syndrome (FAIS) remains uncertain. The factors that may contribute to nonhealing of the joint capsule are
Lin-Yi Shen MM +4 more
doaj +1 more source