Results 201 to 210 of about 82,544 (253)
Mg–Zn composites with a thickness of 0.21 mm were fabricated using roll bonding of a kirigami‐patterned Mg alloy inlay within a Zn matrix. Thermal activation following this process led to the formation of tailored intermetallic structures, which provided the composite with enhanced flexural strength.
Yaroslav Frolov +4 more
wiley +1 more source
Phase Field Failure Modeling: Brittle‐Ductile Dual‐Phase Microstructures under Compressive Loading
The approach by Amor and the approach by Miehe and Zhang for asymmetric damage behavior in the phase field method for fracture are compared regarding their fitness for microcrack‐based failure modeling. The comparison is performed for the case of a dual‐phase microstructure with a brittle and a ductile constituent.
Jakob Huber, Jan Torgersen, Ewald Werner
wiley +1 more source
Fostering Innovation: Streamlining Magnetocaloric Materials Research by Digitalization
Magnetocaloric cooling (MCE) is an environmentally friendly refrigeration method with great potential. Optimizing MCE materials involves the preparation and screening of large quantities of samples, which in turn generates a large amount of data. A digitalization approach is presented that uses ontologies, knowledge graphs, and digital workflows to ...
Simon Bekemeier +17 more
wiley +1 more source
Building machine‐readable vocabularies for materials science is slow, expert‐driven work. This study benchmarks 13 large language models on two of its first steps: finding candidate terms in engineering articles and deciding where they belong in a class hierarchy.
Thomas Bjarsch +3 more
wiley +1 more source
We develop a data‐driven method to derive the mathematical expressions of the Flory–Huggins interaction parameter χ for the swelling behavior of temperature–responsive hydrogels. Starting from initial assumptions of χ, our workflow combines Bayesian optimization, Flory–Rehner theory, and symbolic regression to generate candidate χ expressions.
Yawen Wang +2 more
wiley +1 more source
The PRIMA Thesaurus for Materials Science and Engineering
The PRIMA Thesaurus is a structured vocabulary designed to improve how materials science data is described and shared. Developed with input from multiple experts, it enables clear documentation of research workflows, data exchange, and reuse across platforms.
Rossella Aversa +8 more
wiley +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Effect of fatigue on joint position sense of the knee
Journal of Orthopaedic Research, 1986AbstractThis study was designed to test position sense of the knee joint before and after fatigue in order to determine whether muscle or capsular receptors are the primary sensors for joint position sense. Reproduction of passive positioning and detection of the onset of motion (kinesthesia) were employed to measure joint position sense.
H B, Skinner +4 more
exaly +3 more sources
Joint position sense in the normal and pathologic knee joint
Journal of Electromyography and Kinesiology, 1991Joint position sense has been suggested to be an important factor in the etiology of degenerative joint disease. It is also believed to be important in the rehabilitative process after reconstructive surgery of the knee. Despite this awareness, in many areas of orthopaedic surgery little effort has been devoted to study of this crucial topic. Therefore,
Harry B Skinner, R L Barrack
exaly +3 more sources
Brain, 1980
The effects of isometric and isotonic force production on perceived static joint position were investigated in 12 adult subjects. The joint examined was the proximal interphalangeal joint of one index finger, and its perceived position was determined from matching movements of the equivalent joint on the other hand. When the perturbed joint was free to
W Z, Rymer, A, D'Almeida
openaire +2 more sources
The effects of isometric and isotonic force production on perceived static joint position were investigated in 12 adult subjects. The joint examined was the proximal interphalangeal joint of one index finger, and its perceived position was determined from matching movements of the equivalent joint on the other hand. When the perturbed joint was free to
W Z, Rymer, A, D'Almeida
openaire +2 more sources
Joint position sense – There׳s an app for that
Journal of Biomechanics, 2016Traditionally, proprioception has been assessed with a passive model, in which an external apparatus moves a body segment. Recently, protocols have been developed based on active movements, which are more representative of functional activities. However, even these approaches require expensive testing equipment and the necessity of a visit to a ...
Elizabeth S, Edwards +3 more
openaire +2 more sources

