An Integrated Fabric‐Pneumatic Soft Sensing System for Multi‐Site Muscle Activity Decoding

open access: yesAdvanced Intelligent Systems, EarlyView.
Fabric‐pneumatic chambers convert muscle deformation into pressure signals without electronics at the body‐contact sensing interface. A unified processing pipeline enables static posture classification, continuous elbow‐angle estimation, forearm gesture recognition, and knee‐movement detection across three anatomical sites.
Qifeng Xun   +3 more
wiley   +1 more source

The Key Technologies and Technological Evolution Mechanisms of Robotic Systems for Fracture Reduction Surgery

open access: yesAdvanced Intelligent Systems, EarlyView.
This review traces three decades of technological evolution in robot‐assisted fracture reduction systems, from early robotic concepts to clinically oriented platforms. Key advances in robotic architecture, navigation, path planning, interaction control, and surgical integration are summarized, while current translational challenges and future ...
Shaolong Kuang   +5 more
wiley   +1 more source

Compliant Footpads Enable Terrain‐Adaptive Hopping in a Monopedal Robot

open access: yesAdvanced Intelligent Systems, EarlyView.
A lightweight compliant footpad with embedded spines lets a monopedal hopping robot keep stable ground contact. It preserves stance‐phase dynamics and enables reliable hopping on rock, sand, and ice. Monopedal hopping robots offer exceptional mobility over discontinuous terrain but require consistent foot‐ground contact to maintain stance‐phase ...
Jeeraphat Owen Kledkruemas   +3 more
wiley   +1 more source

Biomechanic and Energetic Effects of a Quasi-Passive Artificial Gastrocnemius on Transtibial Amputee Gait

open access: yesJournal of Robotics, 2018
State-of-the-art transtibial prostheses provide only ankle joint actuation and thus do not provide the biarticular function of the amputated gastrocnemius muscle.
Michael F. Eilenberg   +2 more
doaj   +1 more source

Implantable Systems for Cardiovascular Treatment and Monitoring: Comparative Insights From Intracardiovascular and Extracardiovascular Technologies

open access: yesAdvanced Intelligent Systems, EarlyView.
A unifying device–cardiovascular interface framework is presented to classify implantable cardiovascular technologies as intracardiovascular blood‐contacting systems or extracardiovascular tissue‐only and blood‐handling architectures. Cross‐class comparison across shared semiquantitative criteria, including blood‐contact burden, biomimicry ...
Bergo Nicolò   +7 more
wiley   +1 more source

Finite element analysis of intraosseous distal radioulnar joint prosthesis. [PDF]

open access: yesBMC Musculoskelet Disord, 2022
Gholamian F, Ashrafi M, Moradi A.
europepmc   +1 more source

An Active Knee–Ankle–Foot Orthosis With Torque‐Dense, Low‐Impedance Knee Actuation

open access: yesAdvanced Intelligent Systems, EarlyView.
This article presents the simulation, design, and clinical validation of a robotic active KAFO with torque‐sensitive actuation. By passively and continuously adapting the transmission ratio in response to the knee torque, the torque‐sensitive actuator overcomes the tradeoff between torque, weight, and impedance observed in conventional robot actuators,
Brendon Ortolano   +4 more
wiley   +1 more source

Analysis of contact pressure in a 3D model of dual-mobility hip joint prosthesis under a gait cycle. [PDF]

open access: yesSci Rep, 2023
Tauviqirrahman M   +7 more
europepmc   +1 more source

Performance of the resurfaced hip. Part 1: the influence of the prosthesis size and positioning on the remodelling and fracture of the femoral neck

open access: yes, 2009
Hip resurfacing is an established treatment for osteoarthritis in young active patients. Failure modes include femoral neck fracture and prosthesis loosening, which may be associated with medium-term bone adaptation, including femoral neck narrowing and ...
Taylor, Andrew C.   +5 more
core   +1 more source