Results 101 to 110 of about 239,050 (289)

Artificial structures for human‐machine interfaces with closed‐loop interaction

open access: yesFlexMat, EarlyView.
Artificial structures bridge sensing and feedback in closed‐loop human‐machine interfaces by providing geometry‐enabled mechanical and functional programmability. This review maps the role of artificial structures in diverse sensing modalities and feedback strategies, and illustrates their integration into closed‐loop interaction systems, highlighting ...
Taiqi Hu   +4 more
wiley   +1 more source

Junctional ectopic tachycardia with a benign course in a premature infant.

open access: yes, 1990
The case of a premature baby with junctional ectopic tachycardia is described. The arrhythmia had an unusually benign course, contrary to what has been reported in the literature.
Bolens M   +3 more
core   +1 more source

Electronic Devices and Digital Therapeutics in Neuromuscular Diseases: Narrative Review on Current Applications in Patients' Management and Pharmacovigilance

open access: yesHealth Care Science, EarlyView.
Digital innovations are revolutionizing neuromuscular disease management by integrating wearable sensors, mobile applications, and telemedicine to enable continuous monitoring and personalized care. These technologies enhance diagnosis, treatment, and drug development fostering dynamic interaction between patients and clinicians paving the way toward ...
Ilaria Saltarella   +8 more
wiley   +1 more source

High‐Grade B‐Cell Lymphoma With 11q Aberration in Africa: A Differential Diagnosis in Cases With Features of Endemic Burkitt Lymphoma

open access: yesInternational Journal of Cancer, EarlyView.
ABSTRACT Fifty years ago, Zech et al. in this journal described for the first time the t(8;14) as a recurrent chromosomal aberration in Burkitt lymphoma (BL). Nevertheless, in regions where BL is not endemic, a subset of lymphomas with features of BL lacks the t(8;14)/IG::MYC and instead represents high‐grade B‐cell lymphoma with 11q aberration (HGBCL ...
Timothy Onyuma   +23 more
wiley   +1 more source

Complete AV block, junctional escape rhythm, and ventriculophasic sinus arrhythmia

open access: yes, 1997
Complete AV block is seen as evidenced by the AV dissociation. A junctional escape rhythm sets the ventricular rate at 45 bpm. The PP intervals vary because of ventriculophasic sinus arrhythmia; this is defined when the PP interval that includes a QRS ...
Yanowitz, Frank G.
core  

Severe hypotension during junctional rhythm in a patient with multiple cerebral infarcts. [PDF]

open access: yesJ Cardiol Cases, 2023
Misumi I   +6 more
europepmc   +1 more source

Metabolic Dysfunction‐Associated Steatotic Liver Disease and Obesity: Pathogenesis, Diagnostics, Risk Stratification, and Therapeutic Approach

open access: yesThe Kaohsiung Journal of Medical Sciences, EarlyView.
ABSTRACT Metabolic dysfunction‐associated steatotic liver disease (MASLD) has emerged as the most prevalent chronic liver disease worldwide, closely linked to the global rising incidence of obesity and metabolic syndrome. This review synthesizes current evidence on the pathogenesis, gut–liver axis, and multidisciplinary management of MASLD within the ...
Beom Kyung Kim
wiley   +1 more source

Ventricular paired pacing to control intractable junctional tachycardia following open heart surgery in a child.

open access: yes, 1989
A 5-month-old girl presented postoperatively with an atrioventricular (A-V) junctional tachycardia at a rate of 245/min following surgical repair of tetralogy of Fallot.
Sluysmans, Thierry   +5 more
core   +1 more source

Home - About - Disclaimer - Privacy