Results 31 to 40 of about 9,020 (66)

Kegagalan Alat Flue Gas Desulphur Terhadap Tegangan Lewat Denyar Isolator di Gardu Induk Pembangkitan Tanjung Jati B Jepara

open access: yesMajalah Ilmiah Teknologi Elektro, 2014
Tegangan lewat denyar ( flashover ) adalah  fenomena pelepasan muatan  bersifat merusak yang melintasi  seluruh bagian permukaan isolator. Pelepasan muatan ini disebabkan pembebanan medan listrik pada permukaan isolator yang melebihi harga ketahanan ...
Tedy Juliandhy   +2 more
doaj  

Analisis Hasil Pengujian Tahanan Isolasi Transformator Daya Berdasarkan Hasil Uji Indeks Polarisasi, Tangen Delta, Rasio Tegangan, BDV(Break Down Voltage) [PDF]

open access: yes, 2018
Power transformer is main equipment in electric power systems that connect directly with electrical transmission and distribution systems. One of the most important parts of a power transformer is isolation system.
, Agus Supardi, S.T., M.T   +1 more
core  

Pengaruh Bentuk Dan Material Elektrode Terhadap Partial Discharge

open access: yesJurnal Teknik ITS, 2015
Partial discharge (peluahan sebagian) merupakan suatu fenomena yang terjadi pada tegangan tinggi. Secara definisi, partial discharge adalah terjadinya pelepasan muatan bunga api listrik yang terjadi pada isolasi suatu bahan.
Wildan Rahadian Putra   +2 more
doaj  

Sifat Dielektrik Campuran Gas CO2 dengan Nitrogen (N2) Dibawah Terpaan Medan Tinggi DC Polaritas Positif [PDF]

open access: yes, 2017
Sulfur hexafluoride gas (SF6) is widely used in the power electrical system such as circuit breaker, gas insulated switchgear (GIS) and gas insulated line (GIL).
Anderson, M. (Michael)   +1 more
core  

Analisa Minyak Transformator Pada Transformator Tiga Fasa Di PT X [PDF]

open access: yes, 2016
Tangen delta merupakan metoda diagnostik secara elektrikal untuk mengetahui kondisi isolasi. Salah satu isolasi yang perlu diketahui adalah minyak transformator yang merupakan isolasi cair. Pada sebuah transformator, isolasi merupakan bagian penting yang
Badaruddin, B. (Badaruddin)   +1 more
core  

Diagnosis Kondisi Transformator Berbasis Analisis Gas Terlarut Menggunakan Metode Sistem Pakar Fuzzy [PDF]

open access: yes, 2015
Dissolved gas analysis of transformer oil is one of the most effective ways to determine the transformer condition. Currently, there are many interpretation techniques that have been used in data processing of dissolved gas analysis results. However, all
Nurhasanah, R. (Rini)   +2 more
core  

Analisis Pengaruh Pembebanan terhadap Kekuatan Dielektrik Minyak Isolasi Transformator 6,6 KV/380 V di PT.INTIBENUA PERKASATAMA Dumai [PDF]

open access: yes, 2017
The increment of electric energy comsumption causes the transformer to experience a high load and needs to be detected and treated to increase reability and reduce failure. Dielectric strength is one of detection parameter used.
Firdaus, F. (Firdaus)   +1 more
core  

Studi Tegangan Tembus Minyak Kemiri Sunan Sebagai Alternatif Pengganti Minyak Transformator Daya [PDF]

open access: yes, 2016
Liquid insulation on high voltage equipment is used as the cooling medium of power equipment. If the applied voltage exceeds the dielectric strength of the insulation liquid, breakdown voltage will occur which signifies insulation failure.
Abduh, S. (Syamsir)   +1 more
core  

Karakteristik Tegangan Tembus Arus Bolak Balik pada Minyak Jarak Pagar (Jatropha Curcas) sebagai Alternatif Isolasi Cair [PDF]

open access: yes, 2017
Oil insulation generally use mineral oil because it has good heat absorption and dielectric characteristics as an insulator. Because of mineral oil is less friendly environmental, so important to find a solution to overcome them.
Murdiya, F. (Fri), Putra, R. K. (Rendy)
core  

Perancangan Alat dan Pengujian Tegangan Tembus dengan Minyak Isolasi RBDPO Olein Menggunakan Elektroda Bola-Bola [PDF]

open access: yes, 2017
The crude oil based transformer insulation has several issues i.e. non-environment friendly, non-biodegradable, non-reneweble, and rarely. Vegetable oil is an alternative transformer insulation which is Crude Palm Oil based RBDPO Olein.
Murdiya, F. (Fri), Setiawan, R. (Rudi)
core  

Home - About - Disclaimer - Privacy