Results 51 to 60 of about 416,652 (269)
Early and late results of the GUEPAR hinge knee prosthesis were evaluated on a series of 184 operations performed before January 1st, 1974. There were 3 immediate deaths and 26 before 5 years. Nineteen prostheses were removed. One hundred and twenty-six knees had degenerative osteoarthritis, 52 rheumatoid arthritis.
Aubriot, J.-H. +2 more
openaire +2 more sources
Muscle Control of an Extra Robotic Digit
This study compares muscle‐ and movement‐based control for operating a supernumerary robotic thumb. While movement control performs better in the proposed tasks, muscle‐based (EMG) control promotes broader motor learning. The results highlight the promise and challenges of using biosignals for human augmentation, offering new insights into intuitive ...
Julien Russ +7 more
wiley +1 more source
Background Establishing gait symmetry is a major aim of amputee rehabilitation and may be more attainable with powered prostheses. Though, based on previous work, we postulate that users transfer a previously-learned motor pattern across devices ...
Andrea Brandt +4 more
doaj +1 more source
In orthopaedic technology unilateral leg amputees are provided with prosthesis which are attached through a shaft to the remaining part of the leg.
Subke Joerg +5 more
doaj +1 more source
Introduction: Anterior knee pain (AKP) may persist after total knee arthroplasty (TKA), even if well aligned and stable, and is reported in up to 30% of patients, leading to patient dissatisfaction.
Pongcharoen Boonchana +2 more
doaj +1 more source
Time History Gaussian Process Regression for Modeling the Dynamics of Ankle Exoskeleton User Comfort
Exoskeletons need to be comfortable, but the perception of comfort may change over time. This study investigated if short‐term time history directly influences comfort. No previous trials’ input features were predictive of comfort. Including the previous trial's comfort score marginally improved model accuracy compared to a model using only the current
Axl Maberry, Bo Cheng, Anne E. Martin
wiley +1 more source
To evaluate motions and joint reaction forces of the total knee prosthesis during deep knee flexion such as kneeling and sitting straight, a simulator that reproduces the passive motion of the knee has been developed. The main feature of the simulator is
Yasuju TAKANO +5 more
doaj +1 more source
Dynamic coupling characteristics of a semiactive knee prosthesis
This paper characterises the dynamic coupling interaction between the thigh and an electrical semi-active above knee prosthesis. This prosthetic knee works as a passive knee in part of the gait cycle phases and as an active knee prosthesis during other ...
Dehghani, A +7 more
core +1 more source
Wearable E‐Textiles for Cardiovascular Monitoring: Materials, Devices, and Integrated Systems
The graphical abstract highlights the role of conductive materials and textile fabrication techniques in enabling smart textiles for cardiovascular applications. It showcases textile‐based ECG monitoring, pulse sensing, hemodynamic monitoring, and cardiovascular tissue engineering, while emphasizing the challenges and design considerations that govern ...
Bangul Khan +3 more
wiley +1 more source
A Two‐Stage Characterization Pipeline and Open‐Source Framework for Reproducible Tactile Sensing
The same soft tactile sensor returns different numbers when embodied in different robots. This is an Embodiment Gap that no shared framework currently captures transparently. A two‐stage characterization pipeline, paired with a FAIR open‐source digital datasheet, decouples intrinsic sensor behavior from embodiment effects and condenses cross‐laboratory
Matteo Lo Preti +6 more
wiley +1 more source