Results 51 to 60 of about 235 (135)
Transformer faults can cause power outages, equipment damage, and costly repairs, making early detection critical. Traditional diagnostic methods like dissolved gas analysis (DGA) and frequency response analysis (FRA) are useful, but they often struggle with noisy, overlapping signals, and varying operating conditions.
Fatemeh Ghanadian +4 more
wiley +1 more source
Pulse multiplication in AC–DC converters for harmonic mitigation in vector-controlled induction motor drives [PDF]
In this paper, an autotransformer with reduced kilovoltampere rating for 24-pulse ac-dc converter fed vector controlled induction motor drives (VCIMDs) is presented for harmonic current reduction.
Singh, B. +3 more
core +1 more source
Complex diagnostics of the autotransformer AT-1 of Klaipėda 330/110/10kV transformer substation. [PDF]
This final project is associated with AB „LITGRID“ request, in witch the client required to perform major complex Klaipėda 330/110/10kV transformer substation autotransformer AT-1 measurements, oil chemical and chromatographic analysis of the key ...
VAITKEVIČIUS, Darius,
core
A virtual laboratory for an enhanced and safe understanding of the electric transformers operation [PDF]
[EN] The paper presents an educational software designed to simulate the behaviour of an electric transformer under no-load, shortcircuit and load test, measuring its input and output magnitudes through network analysers, and enabling the supply voltage ...
Bernal-Perez, Soledad +3 more
core +1 more source
Abstract Geomagnetically induced current (GIC) measurements made at two 3 phase, 3 limb transformers, operating in the Halfway Bush substation in Dunedin, New Zealand have been analyzed during the May 2024 Gannon Storm. GIC measurements were combined with very low frequency radio wave AC harmonic measurements made nearby, and reactive power ...
M. A. Clilverd +11 more
wiley +1 more source
Symetrizing Autotransformer [PDF]
Tato bakalářská práce se zabývá problematikou symetrizace odběru v distribuční soustavě. Na úvodních stránkách je popsána problematika symetrizace odběru elektrické energie, je zde vysvětleno, jak se chovají spotřebiče, které jsou připojeny k ...
Petřík Jan
core
Moisture and temperature effects on power transformer winding clamping pressure [PDF]
This paper presents findings from a finite element modelling based simulation study conducted to understand the moisture and temperature dependency of power transformer winding clamping pressure.
Ekanayake, Chandima +5 more
core +1 more source
A Modular Multi‐Port Hybrid Solid‐State Transformer for Large‐Scale Renewable Power Applications
This article proposes a four‐port solid‐state transformer (FPSST) to enhance large‐scale energy generation from renewable sources. The FPSST incorporates a modular multilevel converter to collect both medium‐voltage ac and medium voltage dc from wind and solar systems.
Md. Sanwar Hossain +3 more
wiley +1 more source
ABSTRACT Investigation of power converters for use in industrial drive applications finds that these converters are used low reliable components. To overcome this issue, in this paper, advanced power converters (multi‐pulse AC–DC and multilevel DC–AC converter) are developed and implemented to feed vector‐controlled induction motor drive (VCIMD), which
Bhim Singh, Rohit Kumar
wiley +1 more source