Results 191 to 200 of about 39,751 (287)
Elastic constants identification for laminated composites using laser doppler vibrometry and an inversion method based on legendre orthogonal polynomial expansion. [PDF]
Liu H +6 more
europepmc +1 more source
This study introduces a novel metamaterial absorber integrating water as a lossy medium with patterned indium tin oxide (ITO) films to achieve simultaneous optical transparency and ultra‐wideband electromagnetic absorption over 0.52‐40 GHz. It effectively overcomes the limitations of conventional opaque and bulky shielding materials, offering a ...
Xiaojun Huang +5 more
wiley +1 more source
Static and Vibration Analysis of Imperfect Thermoelastic Laminated Plates on a Winkler Foundation. [PDF]
Liu J +5 more
europepmc +1 more source
Reliable soft sensors are essential for precise control in soft medical robots such as endoscopes. We developed ultrathin silicon piezoresistive sensors and their oil‐lubricated slidable packaging, which enables high‐fidelity shape sensing of silicon gauges by mechanically isolating the sensing element within a dual‐layer film.
Hao Liu +7 more
wiley +1 more source
The Research on Multi-Process Collaborative Manufacturing and Characterization Methods of Micro-Nano-Composite Layered Structures. [PDF]
Xu S +7 more
europepmc +1 more source
Progressive stiffening of the hepatic extracellular matrix and free fatty acid overload activate the mechanosensor Piezo1 in steatotic hepatocytes, inducing calcium influx and nuclear translocation of Yes‐associated protein. YAP‐dependent nuclear signaling further drives inflammatory and fibrotic gene programs, lipid metabolic reprogramming, and ...
Juan Ma +15 more
wiley +1 more source
Selective Reinforcement Optimization for Composite Laminates. [PDF]
Balashov A +3 more
europepmc +1 more source
Compliant Polymeric Sheet‐Based Heat Exchangers
This work presents flexible, transparent, and deployable polymer heat exchangers that achieve a heat transfer capacity per cost up to 4x higher than the state of the art, surpassing both metal and other polymer counterparts. The tube‐on‐tube design enables efficient heat transfer without flow occlusion, while the lightweight, corrosion‐resistant, and ...
Richard J. Fontenot +5 more
wiley +1 more source
High electrical performance alone does not guarantee efficient bioelectronic signal transduction. Despite excellent mixed ionic‐electronic conduction, recordings from cardiomyocytes reveal that p(g2T‐TT)‐based OECTs predominantly transduce field potential FP‐like signals due to weak cell‐polymer coupling.
Giulia Zoe Zemignani +10 more
wiley +1 more source

