Results 71 to 80 of about 2,266 (227)
Ada dua jenis sambungan tulangan pada pekerjaan kolom yaitu: lap splice dan mechanical splice. Sambungan lap splice adalah metode tradisional untuk menyambungkan kedua tulangan.
Aurick, Kevin
core
ABSTRACT This article presents a capacity‐based assessment procedure for beam–column (b–c) joints of reinforced concrete frames with floor slabs and transverse beams. The procedure extends a previously proposed assessment methodology for determining the hierarchy of strengths and the sequence of events in symmetrically reinforced planar b–c joints.
Patricio Quintana Gallo +3 more
wiley +1 more source
ABSTRACT Issue Addressed Swimming lessons are an effective drowning prevention strategy, yet uptake remains socially patterned. Socio‐structural factors such as parent age, sex and family income may shape parents' decisions to enrol their children in swimming lessons.
Kyra Hamilton +5 more
wiley +1 more source
Abstract The study was conducted in Brazil and aimed to systematically review empirical research examining the association between maternal indicators of anxiety, stress, and depression and the developmental outcomes of preterm children. A literature search was conducted across PubMed, Web of Science, PsycINFO, EMBASE, Scopus, LILACS, and SciELO ...
Bianca Basso Rustiguelli da Silva +1 more
wiley +1 more source
ABSTRACT Background Metabolic dysfunction‐associated fatty liver disease (MASLD) is the most prevalent chronic liver disease globally. Early screening is critical for preventing liver fibrosis (LF) and cirrhosis, but liver biopsy and imaging are costly and less accessible in primary care settings.
Huiya Huang +8 more
wiley +1 more source
Effect of Simulated Cracks on Lap Splice Strength of Reinforcing Bars [PDF]
The effect of preexisting cracks, oriented in the plane of and parallel to the reinforcing steel, on the strength of No. 11-bar lap splices was investigated by testing six beams – three with a splice length of 79 in.
Yuan, Jiqiu +3 more
core
Design standards necessitate the use of a sufficient lap splice length when dealing with longer spans of Reinforced Concrete (RC) members. An inadequate lap splice length results in a reduction of both the flexural strength and ductility of reinforced ...
Ali Mohamed Abdallah +5 more
doaj +1 more source
Many research studies have been carried out on the different parameters affecting the bond strength of tension lap splices in RC beams but limited attention has been given to the effect of using transverse reinforcement along the splice length. The first
Rasha T.S. Mabrouk, Ahmed Mounir
doaj +1 more source