Results 181 to 190 of about 12,287 (261)

Group‐Patch Joint Compression: Compressing Dynamic B0 and Static RF Spatial Modulations Across k‐Space Subregion Groups for Highly Accelerated MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To accelerate MRI further, rapid B0 field modulations can be applied during oversampled readout to capture additional physical information, as in Wave‐CAIPI/FRONSAC/local B0 coils modulation techniques. These methods, however, turn the Fourier readout into a non‐Fourier‐encoded dimension that cannot be reconstructed by FFT, posing ...
Rui Tian, Klaus Scheffler
wiley   +1 more source

Dynamic slip wall model for large-eddy simulation. [PDF]

open access: yesJ Fluid Mech, 2019
Bae HJ   +3 more
europepmc   +1 more source

View Order With Arbitrary Center Echoes

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To provide explicit, vendor‐independent view‐order constructions that enable selection of an arbitrary center echo in multi‐shot imaging, with a focus on RARE and MPRAGE. Methods Vendor‐independent view‐order methods were developed to assign echo and shot indices to a prescribed set of phase encodes, enabling explicit selection of the ...
Henric Rydén   +4 more
wiley   +1 more source

Real‐Time Targeted Slice Reacquisition for Motion‐Corrupted Fetal Diffusion MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop and evaluate a real‐time framework for targeted slice‐level reacquisition in fetal diffusion MRI. Methods A DW‐SE‐EPI sequence was modified to support independent diffusion preparation per slice. A pathology‐robust nnU‐Net segmentation network, updated from a previously published baseline (V1) using pathological fetal cases ...
Jordina Aviles Verdera   +7 more
wiley   +1 more source

A Deep Nonlinear Subspace Modeling and Reconstruction for Diffusion‐Weighted Imaging Using Denoising Auto‐Encoder

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To present a novel, nonlinear subspace modeling and joint k–q‐space reconstruction technique for high‐resolution, multi‐band, multi‐shell diffusion‐weighted imaging (DWI). Methods High b‐value (> 1000 s/mm2), high resolution DWI has the drawback of generally low signal‐to‐noise ratios (SNRs).
Julius Glaser   +4 more
wiley   +1 more source

Comparative Systematic Analysis of Gray Matter Biophysical Models on a Public Dataset

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Biophysical models of diffusion tailored to characterize gray matter (GM) microstructure are gaining traction in the neuroimaging community. NEXI, SMEX, SANDI, and SANDIX represent recent efforts to account for different microstructural features, such as soma contributions and inter‐compartment exchange, in the diffusion MRI (dMRI ...
Santiago Mezzano   +6 more
wiley   +1 more source

Combined ADC and T2 Mapping in the Prostate Using a 3D Reduced FOV Sequence

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a 3D reduced FOV sequence for combined ADC and T2 mapping in the prostate in a single scan. Methods A 3D ADC and T2 mapping reduced FOV acquisition is enabled using T2 and diffusion preparation modules with slab‐selective tip‐down pulses and magnitude stabilizer gradients.
Yannik Ott   +8 more
wiley   +1 more source

Turbulence intensities in large-eddy simulation of wall-bounded flows. [PDF]

open access: yesPhys Rev Fluids, 2018
Bae HJ   +3 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy