Optimization of Gradient Pulse Shape Prediction Using Temporal Convolutional Networks

open access: yesMagnetic Resonance in Medicine, EarlyView.
Purpose To improve TCN‐based gradient‐waveform prediction with respect to acquisition efficiency and inference speed, and to evaluate its use for radial imaging. Methods Gradient waveforms were measured using a thin‐slice method on a preclinical MRI system. Separate TCN models were trained for each physical gradient axis to predict both gradient and B0$
Jiří Vitouš   +2 more
wiley   +1 more source

Self‐Correction of B0 Drift and Trajectory Error in Alternating Unbalanced SSFP‐FID and SSFP‐ECHO (AUSFIDE)‐Based 3D Transverse Relaxometry of the Human Brain

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose The alternating unbalanced SSFP (AUSFIDE) pulse sequence, which consists of multi‐echo trains of SSFP‐FID and SSFP‐ECHO modules, enables rapid estimation of R2 and R2′, but is prone to errors from temporal drift of the main magnetic field (B0) and k‐space trajectory mismatch.
Eunseo Bae   +5 more
wiley   +1 more source

The b‐Value Dependence for Higher‐Degree Spherical Harmonic Powers of the Diffusion MRI Signal Follows Stick Model Predictions in White Matter

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To compare the dependence on b‐value of the spherical harmonic powers for the diffusion MRI signal in white matter to theoretical predictions from the stick model of water diffusion within axons. Methods Diffusion MRI data were acquired at 3 T in three healthy adults with 10 b‐value shells (b = 1000–10 000 s/mm2) and 64 directions per ...
Hunter G. Moss   +2 more
wiley   +1 more source

Assessment of RF‐Induced Heating of Stainless‐Steel Sternal Wires at 7 T MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To investigate RF‐induced heating of stainless‐steel sternal closures at 7 T proton MRI for simple loop and figure‐of‐8 configurations. Methods Simple loop and figure‐of‐8 sternal closure designs were implemented on plexiglass rods and immersed in a hydroxyethyl‐cellulose phantom.
Mathijs W. I. Kikken   +6 more
wiley   +1 more source

Stim‐CODE: PNS and CNS Constraint Optimized Diffusion‐Encoding for Neuroimaging on 200 mT/m Whole‐Body Gradients

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Ultra‐high‐performance whole‐body MRI gradients (Gmax$$ {G}_{\mathrm{max}} $$ ≥$$ \ge $$ 200mT/m, Smax$$ {S}_{\mathrm{max}} $$ ≥$$ \ge $$ 200 T/m/s) can reduce echo times (TE) in diffusion‐weighted imaging (DWI), improving SNR. However, full hardware utilization is limited by cardiac (CNS) and peripheral (PNS) nerve stimulation ...
Ariel J. Hannum   +6 more
wiley   +1 more source