Results 41 to 50 of about 180,806 (262)

An Inexpensive, 3D-Printable, Arduino- and Blu-Ray-Based Confocal Laser and Fluorescent Scanning Microscope

open access: yesMetrology
There is a growing field that is devoted to developing inexpensive microscopes and measurement devices by leveraging low-cost commercial parts that can be controlled using smartphones or embedded devices, such as Arduino and Raspbery Pi. Examples include
Justin Loose   +7 more
doaj   +1 more source

RoundMi: A quantitative method to analyze mitochondrial morphology in mitotic cells

open access: yesFEBS Open Bio, EarlyView.
RoundMi is a workflow for rapid analysis of mitochondrial morphology in mitotic cells. By combining adaptive preprocessing with automated segmentation and quantification, it enables accurate measurements from single focal plane images, reducing acquisition time and computational demands while remaining compatible with high‐throughput fixed and live ...
Elmira Parvindokht Bararpour   +2 more
wiley   +1 more source

Microanatomy of the Rat Diaphragm: A Scanning Electron and Confocal Laser Scanning Microscopic Study.

open access: yesArchives of Histology and Cytology, 1993
The present study demonstrated the three-dimensional microstructure of the rat diaphragm by scanning electron microscopy (SEM) of either intact or alkali-treated tissues, enzyme-histochemistry, and confocal laser scanning microscopy (LSM). The peritoneal and pleural surfaces of the diaphragm were covered with mesothelial cells studded with microvilli ...
Ohtani, Yuko   +2 more
openaire   +3 more sources

Lipopolysaccharide uptake is augmented in lipopolysaccharide‐tolerant mouse macrophage‐like cells via increased CD14 expression

open access: yesFEBS Open Bio, EarlyView.
In normal (nontolerant) cells, CD14 is crucial for both LPS uptake and LPS signaling. In LPS‐tolerant cells, in which LPS‐induced TNF‐α and IFN‐β production is suppressed, there is a dramatic increase in surface CD14 expression. The overexpressed CD14 in LPS‐tolerant cells is responsible for the enhanced LPS uptake without inducing pro‐inflammatory ...
Saeka Nishihara   +3 more
wiley   +1 more source

A new flow chip in combination with multiphoton microscopy as a protocol for longitudinal 3D imaging of tissue calcification under shear stress

open access: yesFEBS Open Bio, EarlyView.
Miniaturized flow chip platform enabling continuous perfusion and longitudinal multiphoton 3D imaging of vascular smooth muscle cell constructs under physiological flow. Brightfield imaging guides region selection, while CellTracker Green and mRuby‐labeled fetuin‐A visualize cells and mineral deposition, respectively. Magnesium supplementation markedly
Vytautas Kučikas   +6 more
wiley   +1 more source

A Sensitive Thresholding Method for Confocal Laser Scanning Microscope Image Stacks of Microbial Biofilms

open access: yesScientific Reports, 2018
Biofilms are surface-attached microbial communities whose architecture can be captured with confocal microscopy. Manual or automatic thresholding of acquired images is often needed to help distinguish biofilm biomass from background noise.
Ting L. Luo   +6 more
doaj   +1 more source

Antinuclear human autoantibodies as markers in Nicotiana tabacum pollen tubes

open access: yesActa Societatis Botanicorum Poloniae, 2014
In the present paper we report on the use of antinuclear human autoantibodies as specific markers in Nicotiana tabacum pollen tubes. The antibodies have been tested by fluorescence techniques using a confocal laser scanning microscope. All the antibodies
C. Poggialini   +5 more
doaj   +1 more source

β‐Catenin/c‐Myc Axis Modulates Autophagy Response to Different Ammonia Concentrations

open access: yesAdvanced Biology, Volume 9, Issue 3, March 2025.
Ammonia, detoxified by the liver into urea and glutamine, impacts autophagy differently at varying levels. Low ammonia activates autophagy via c‐Myc and β‐catenin, while high levels suppress it. Using Huh7 cells and Spf‐ash mice, c‐Myc's role in cytoprotective autophagy is revealed, offering insights into hyperammonemia and potential therapeutic ...
S. Sergio   +11 more
wiley   +1 more source

Carboxylic‐Acid Functionalized Multiwalled Carbon Nanotube‐Alkane‐Based Resistive Temperature Sensor for Cold Chain Applications

open access: yesAdvanced Engineering Materials, EarlyView.
This study presents a reversible temperature sensor with high switching ratio, ∼103. The device is fabricated using PET‐ITO and carbon nanotube dispersions in alkane. Considering its application in cold chain logistics, a proof‐of‐concept with LED is showcased. Thus, a temperature drop below the threshold temperature (crystallization temperature of the
Sunil Kumar Behera   +8 more
wiley   +1 more source

Design of a quantum diamond microscope with efficient scanning confocal readout

open access: yesAcademia Quantum
In this paper we introduce the light-sheet confocal quantum diamond microscope (LC-QDM) for widefield 3D quantum sensing with efficient confocal readout.
Daniel G. Ang   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy