Results 11 to 20 of about 144 (113)
This study conducted a comparative evaluation of two bearingless cross-flow fan designs for applications in deep ultraviolet lithography excimer lasers, where maximizing the speed and power of the fan has a direct influence on the throughput and scanning
Ivana Bagaric +4 more
doaj +1 more source
Pulsed laser deposition of oxide thin films by the fifth harmonic of a Nd:Y3Al5O12 (Nd:YAG) laser
We report the pulsed laser deposition (PLD) of anatase TiO2, LaAlO3, and La0.7Ca0.3MnO3 epitaxial thin films by a fifth-harmonic Nd:Y3Al5O12 (Nd:YAG) laser.
Ryota Shimizu +4 more
doaj +1 more source
Background To compare the visual and refractive outcomes after myopic LASEK using three different excimer lasers and standardized surgical and mitomycin C (MMC) application protocols. Methods In this retrospective, observational cohort study, we examined
Isabel Rodríguez-Pérez +4 more
doaj +1 more source
The crystallization of hydrogenated amorphous silicon (a-Si:H) is essential for improving solar cell efficiency. In this study, we analyzed the crystallization of a-Si:H via excimer laser annealing (ELA) and compared this process with conventional ...
Sanchari Chowdhury +7 more
doaj +1 more source
Seasonal changes and varying degree of corneal hydration has been linked to excimer laser corneal ablation rates. The use of PMMA as a calibration material in refractive lasers is well established.
Shwetabh Verma +2 more
doaj +1 more source
Purpose. To evaluate visual and refractive results of FemtoLASIK using the WaveLight EX 500 and Microscan Visum excimer laser systems in patients with low to moderate myopia.Material and methods.
A. V. Doga +4 more
doaj +1 more source
Purpose. To compare clinical outcomes following LASIK for myopia performed with MEL 90 vs. Schwind Amaris 750S excimer laser. Methods. Data were collected retrospectively for patients who underwent Femto-LASIK, using the MEL 90 and Schwind Amaris 750S ...
Sheetal Brar +3 more
doaj +1 more source
Shielding effect of the smoke plume by the ablation of excimer lasers
Background Shielding and scattering effect of the smoke plume column ejected from the laser ablated material is a well-known phenomenon. Debris evacuation system of the excimer laser equipment removes these particles, but insufficient air flow can result
Csaba Szekrényesi +3 more
doaj +1 more source
Lasers for the treatment of coronary artery disease: An update
In the present era, percutaneous coronary intervention is being done for various types of coronary lesions worldwide. However, calcified and fibrotic lesions have remained a major challenge in coronary interventions.
Akshyaya Pradhan +2 more
doaj +1 more source
Electrohydrodynamic excimer laser: Ultra-compact system and laser energy performance dynamics
Excimer lasers, essential deep ultraviolet gas light sources, have consistently encountered significant challenges in achieving miniaturization while maintaining high performance. These challenges have limited their broader application and development in
Jin-Liang Han +6 more
doaj +1 more source