Results 91 to 100 of about 52,925 (187)
A Comprehensive Study of Cyber Attack Mitigation with the Exchange of Frequency Containment Reserves Control in a Multi-Infeed Direct Current Power System. [PDF]
Ramadhan UF, Lee J, Yoon M.
europepmc +1 more source
Commutation failure (CF) is an inherent problem faced by line commutated converter high voltage direct current (LCC‐HVDC) technology. To completely solve the problem of CF, we have proposed a novel hybrid commutated converter (HCC) technology based on ...
Zongze Wang +7 more
doaj +1 more source
Flexible control switching method for converter station in LCC-HVDC transmission system
Line Commutated Converter based High Voltage Direct Current (LCC-HVDC) transmission technology has the advantages of high withstand voltage and large current capability and has been widely used in renewable energy transmission.
Maolan Peng +5 more
doaj +1 more source
A New Online Power Reversal Strategy for LCC-HVDC Systems Utilizing Round Power Mode
Achieving higher renewable penetration in power systems requires more operational flexibility due to the variability of renewable energy sources. LCC-HVDC systems, boasting the largest installed capacity among existing HVDC technologies, hold tremendous ...
Li, Zhixuan +6 more
core +1 more source
Aiming at the poor voltage response characteristics of the line-committed converter-based high voltage direct current (LCC-HVDC) transmission system after the fault of the AC system at the inverter side, this paper analyzes the relationship between the ...
Dui Liu +5 more
doaj +1 more source
A protection method for multi-terminal HVDC system based on fuzzy approach. [PDF]
Sahu U, Yadav A, Pazoki M.
europepmc +1 more source
MMC HVDC Controls for Damping Subsynchronous Interactions With LCC HVDC and Thermal Generator
This paper develops a subsynchronous damping controller (SSDC) on modular multilevel converter (MMC) HVDC with the aim of mitigating three-way torsional interactions between a line commutated converter (LCC) HVDC, MMC HVDC and a nuclear generator.
Stefan Kovacevic +3 more
doaj +1 more source
The AC transmission line fault near the LCC-HVDC inverter station might lead to commutation failure. And fault voltage and current waveforms would be distorted. It will have an adverse effect on the performance of fundamental power frequency phasor based
Huixin LI +4 more
doaj +1 more source
GADF-VGG16 based fault diagnosis method for HVDC transmission lines. [PDF]
Wu H, Yang Y, Deng S, Wang Q, Song H.
europepmc +1 more source
High-voltage direct current (HVDC) transmission is a crucial way to solve the reverse distribution of clean energy and loads. The line commutated converter-based HVDC (LCC-HVDC) has become a vital structure for HVDC due to its high technological maturity
Bo Pang +6 more
doaj +1 more source