Results 91 to 100 of about 52,925 (187)

Control strategy of novel hybrid commutated converter based on reverse blocking integrated gate commutated thyristor for commutation failure mitigation

open access: yesHigh Voltage
Commutation failure (CF) is an inherent problem faced by line commutated converter high voltage direct current (LCC‐HVDC) technology. To completely solve the problem of CF, we have proposed a novel hybrid commutated converter (HCC) technology based on ...
Zongze Wang   +7 more
doaj   +1 more source

Flexible control switching method for converter station in LCC-HVDC transmission system

open access: yesFrontiers in Electronics
Line Commutated Converter based High Voltage Direct Current (LCC-HVDC) transmission technology has the advantages of high withstand voltage and large current capability and has been widely used in renewable energy transmission.
Maolan Peng   +5 more
doaj   +1 more source

A New Online Power Reversal Strategy for LCC-HVDC Systems Utilizing Round Power Mode

open access: yes
Achieving higher renewable penetration in power systems requires more operational flexibility due to the variability of renewable energy sources. LCC-HVDC systems, boasting the largest installed capacity among existing HVDC technologies, hold tremendous ...
Li, Zhixuan   +6 more
core   +1 more source

Suppression of continuous commutation failure in LCC-HVDC transmission based on improved virtual synchronous generator control for energy storage system

open access: yesInternational Journal of Electrical Power & Energy Systems
Aiming at the poor voltage response characteristics of the line-committed converter-based high voltage direct current (LCC-HVDC) transmission system after the fault of the AC system at the inverter side, this paper analyzes the relationship between the ...
Dui Liu   +5 more
doaj   +1 more source

MMC HVDC Controls for Damping Subsynchronous Interactions With LCC HVDC and Thermal Generator

open access: yesInternational Transactions on Electrical Energy Systems
This paper develops a subsynchronous damping controller (SSDC) on modular multilevel converter (MMC) HVDC with the aim of mitigating three-way torsional interactions between a line commutated converter (LCC) HVDC, MMC HVDC and a nuclear generator.
Stefan Kovacevic   +3 more
doaj   +1 more source

Adaptability Analysis and Countermeasures for Distance Protection of AC Transmission Lines Connected LCC-HVDC Inverter Station

open access: yesZhongguo dianli
The AC transmission line fault near the LCC-HVDC inverter station might lead to commutation failure. And fault voltage and current waveforms would be distorted. It will have an adverse effect on the performance of fundamental power frequency phasor based
Huixin LI   +4 more
doaj   +1 more source

GADF-VGG16 based fault diagnosis method for HVDC transmission lines. [PDF]

open access: yesPLoS One, 2022
Wu H, Yang Y, Deng S, Wang Q, Song H.
europepmc   +1 more source

Transient AC Overvoltage Suppression Orientated Reactive Power Control of the Wind Turbine in the LCC-HVDC Sending Grid

open access: yesCES Transactions on Electrical Machines and Systems
High-voltage direct current (HVDC) transmission is a crucial way to solve the reverse distribution of clean energy and loads. The line commutated converter-based HVDC (LCC-HVDC) has become a vital structure for HVDC due to its high technological maturity
Bo Pang   +6 more
doaj   +1 more source

Home - About - Disclaimer - Privacy