Results 31 to 40 of about 52,925 (187)

Comparison of different technologies for improving commutation failure immunity index for LCC HVDC in weak AC systems [PDF]

open access: yes, 2015
Flexible AC Transmission System (FACTS) devices and Voltage Source Converter (VSC) High Voltage Direct Current (HVDC) systems have fast reactive power control capabilities which can be used to increase power system voltage stability.
Burr, Kelly Joe   +2 more
core   +3 more sources

Economic analysis of flexible LCC-HVDC systems with controllable capacitors

open access: yes, 2022
Commutation failure (CF) is a frequent dynamic event at inverter of LCC-HVDC systems caused by AC side faults which can lead to inverter blocking, interruption of active power transfer, and even system blackout.
Li, Fangling   +5 more
core   +1 more source

Harmonic loss analysis of converter transformer in LCL-HVDC system

open access: yesEnergy Reports, 2020
At present, China’s energy distribution and economic development are extremely unbalanced. In order to make rational use of resources, China has promoted the “west to East power transmission” and “north to South Power Transmission” pattern.
Qing Ni   +3 more
doaj   +1 more source

A Multi-infeed HVDC System: Assessment of Transient Overvoltages

open access: yes, 2021
The paper presents an electromagnetic-transient (EMT) analysis of a multi-infeed HVDC cable system in order to assess the transient overvoltages on the cables due to different fault conditions. It is well known that the HVDC-MMC configuration needs surge
S. DAMBONE SESSA   +5 more
core   +1 more source

Practical calculation of SCR of LCC-HVDC considering the role of VSC-HVDC

open access: yesZhejiang dianli, 2023
The accurate quantification of transmission limit and grid strength of the multi-infeed LCC-HVDC (line-commutated converter technology-based high-voltage DC) and VSC-HVDC (voltage source converter technology-based high-voltage DC) systems has become one ...
YANG Xiaolei   +5 more
doaj   +1 more source

Study on Difference Between Two-Terminal LCC-HVDC and Three-Terminal LCC-HVDC Control and Protection System

open access: yesIOP Conference Series: Earth and Environmental Science, 2021
Abstract The paper studies the difference between two-terminal Line Commutate Converter Based High Voltage Direct Current (LCC-HVDC) and three-terminal LCC-HVDC control and protection system relying on the Yun-gui Interconnection Project of China Southern Grid (CSG).
openaire   +1 more source

LCC-HVDC Bipole System with MMC-Based DC Tapping Stations [PDF]

open access: yes, 2022
Line Commutated Converter based High Voltage DC (LCC-HVDC) is the dominant technology of HVDC power transmission worldwide. LCC-HVDC has lower cost of implementation and lower power losses, accompanied by higher voltage capabilities and higher power ...
Persand, Manish
core   +1 more source

The Simulation Analysis and Countermeasures of LCC-HVDC Complementary Resonance

open access: yesJournal of Physics: Conference Series, 2023
Abstract With the advancement of HVDC technology, the AC/DC hybrid grid has gradually emerged. The interaction and influence between AC and DC have become increasingly prominent, with the complementary resonance problem between AC and DC emerging as a hot research topic.
Yinsheng Su   +5 more
openaire   +1 more source

Power reversal strategies for hybrid LCC/MMC HVDC systems [PDF]

open access: yes, 2020
Power reversal control strategies for different types of hybrid line-commutated-converter (LCC)/modular multi-level converter (MMC) based high-voltage direct-current (HVDC) systems have been proposed with the consideration of system configurations and ...
Lan, Yuanliang   +17 more
core   +1 more source

Three-way Subsynchronous Torsional Interactions Between LCC HVDC, MMC HVDC and a Thermal Generator

open access: yesJournal of Modern Power Systems and Clean Energy, 2023
This paper performs a study on three-way subsynchronous torsional interactions (SSTI) between a hybrid dual-in-feed high-voltage direct current (HVDC) system and a nuclear generator. The test case is based on the French IFA2000 line commutated converter (
Stefan Kovacevic   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy