Design of a robust digital current controller for a grid connected interleaved inverter
This paper is concerned with the design and practical implementation of a robust digital current controller for a threephase voltage source grid-connected interleaved inverter.
Sharkh, S. M., Abu-sara, M. A.
core +1 more source
A Control Strategy of a Single-phase H6-type Grid-connected Inverter with Low Harmonic Current
In order to reduce the total harmonic distortion (THD) of the grid-connected current caused by the high-frequency switching of the inverter, this paper combines the high efficiency single-phase H6-type inverter with LCL filter.
Chunxu Lin +3 more
doaj +1 more source
Design and control of the single-phase H6-type grid-connected inverter with LCL filter
In order to reduce the total harmonic distortion(THD) of the grid-connected current caused by the high-frequency switching of the inverter, this paper combines the high efficiency single-phase H6-type inverter with LCL filter.
Lin Chunxu, Wang Juan, Zhao Wangming
doaj +1 more source
The undamped control for PWM rectifier based on LCL filter [PDF]
LCL filter is applied in PWM rectifier with the better filtering effect. Its inductor also plays a role in inhibiting the current impact, which not only has a good dynamic performance, but also reduces the system cost.
Jiangtao Fu +3 more
core +1 more source
Control strategy of LCL-type three-phase photovoltaic grid connected inverter
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed
WANG Si-hua, WANG Jin-qiang
doaj
Grid-connected electric vehicle charging stations (EVCS) commonly employ LCL filters for harmonic attenuation. Yet, trajectory planning methods typically rely on single-inductance models without providing a formal justification for neglecting filter ...
Joanna Piasek-Skupna, Michal Skupny
doaj +1 more source
Active Damping of LCL-Filter Resonance Using a Digital Resonant-Notch (Biquad) Filter [PDF]
The LCL filter is a fundamental component which interfaces a voltage-source inverter (VSI) with a power grid, but on the other hand, it introduces a potential resonance risk which may be harmful to the system stability.
Wang, Xiongfei; id_orcid +3 more
core +2 more sources
Active Power Filter LCL Filter Insertion Loss Calculation Analysis
This paper introduces a new approach for active power filters LCL filter insertion loss calculation, treating it as two port T-network and describing it using scattering and impedance parameters.
Ašmanis, Aivis +2 more
core
Design of the LCL+trap filter for the two-level VSC installed in a large-scale wave power plant
This paper presents a methodology for designing the link passive filter of the power converters installed in a multi-megawatt wave power plant. Such filter is based on the superposition of both LCL and trap filter configurations with the purpose of ...
Mir Cantarellas, Antonio +7 more
core +1 more source
Generalized design of high performance shunt active power filter with output LCL filter
This paper concentrates on the design, control, and implementation of an LCL-filter-based shunt active power filter (SAPF), which can effectively compensate for harmonic currents produced by nonlinear loads in a three-phase three-wire power system.
Peng Wang +12 more
core +1 more source