Magnetic integration of a symmetrical LCL filter in the grid‐tied inverter with reduced EMI noise
Harmonics and electromagnetic interference (EMI) pose serious threats to the safety and efficiency of grid‐tied inverters. Although the inductor‐capacitor‐inductor (LCL) filter offers commendable harmonic suppression, it does not sufficiently mitigate ...
Xingyu Liu, Yitao Liu, Jian Yin
doaj +2 more sources
Stability of Grid-Connected Inverter with LCL Filter [PDF]
<p>The paper analyses oscillations in a single-phase grid connected inverter with the LCL output filter. Passive and active damping techniques are designed and compared by simulations. The inverter is controlled by a proportional resonant controller.</p>
Marek Pástor, Jaroslav Dudrik
openaire +2 more sources
Linac performance benchmarking: Feasibility of a web-based tool for comparison of local machine performance check (MPC) results with the global community. [PDF]
Abstract Background Varian machine performance check (MPC) is a manufacturer integrated quality control system included as standard for TrueBeam and Halcyon linear accelerators (linacs) to assess performance using a broad range of geometric and beam tests.
May L +12 more
europepmc +2 more sources
Robust repetitive feedback control of a three-phase grid connected inverter [PDF]
This paper discusses the design of a repetitive feedback controller for a grid-connected two-level three-phase voltagesource inverter connected between a DC source and the grid through an LCL filter.
Sharkh, S.M. +4 more
core +3 more sources
An Electrical Machine with Integrated Drive LCL Filter Components [PDF]
In recent years, integrated passive components technology has gained significant popularity in integrated drives research. An integrated drive may be considered to be a full mechanical integration of the machine, power electronic converter and passive components into a single package. This approach is important for applications such as traction motors,
MA Mohamed +4 more
openaire +1 more source
Control strategy of mine-used LCL three-level static var generator
In order to adapt to special environment of coal mine and reduce volume and quality of mine-used static var generator(SVG), LCL filter and three-level inverter were used as main circuit topology of mine-used SVG.
ZHANG Chuanjin +4 more
doaj +1 more source
Single-Sensor Control of LCL-Filtered Grid-Connected Inverters [PDF]
Owing to the filter resonance and background harmonics, the current control for the LCL-filtered grid-connected inverter should be carefully designed to ensure stable operation. Prior-art current control methods normally require extra sensors to achieve the damping of the resonance, or sophisticated active damping should be employed.
Mei Su 0001 +7 more
openaire +4 more sources
Adequate Tuning of LCL filter for Robust Performance of Converter Side Current Feedback Control of Grid Connected Modified–Y-Source Inverter [PDF]
In the grid-tied PV inverter systems, the design of a proper power conditioning system is an important issue to ensure high-quality power injection to the grid.
Navid Rasekh, Majid Hosseinpour
doaj +1 more source
Research on Current Harmonic Suppression Strategy of the LCL Grid-connected Inverter [PDF]
The increasing number of nonlinear devices increased the harmonic content of grid voltage background and led to the grid-connected current distortion of inverter.
LIU Haiyang +4 more
doaj +1 more source
Analysis and design of LCL filter based synchronverter [PDF]
Electrical energy generation is evolving from centralized towards distributed energy resources (DER) like wind and solar power plants. In such power systems, new challenges arise for the design of voltage source converter (VSC) control strategies.
Rosso, Roberto +4 more