Results 191 to 200 of about 5,121 (217)
Some of the next articles are maybe not open access.

Design of LCL Filter

2017
As the interface between renewable energy power generation system and the power grid, the grid-connected inverter is used to convert the dc power to the high-quality ac power and feed it into the power grid. In the grid-connected inverter, a filter is needed as the interface between the inverter and the power grid.
Xinbo Ruan   +5 more
openaire   +1 more source

Spread Spectrum Modulation for LCL Filter Design

2019 20th International Symposium on Power Electronics (Ee), 2019
The LCL filter is often the bulkiest component in grid-tied converters, which is designed to satisfy the grid harmonic standards such as IEEE519. To reduce the filter requirement, application of the spread spectrum modulation (SSM) to LCL filter design is investigated in this paper.
Ki-Bum Park   +2 more
openaire   +1 more source

Magnetic Integration of LCL Filters

2017
An LCL filter has two individual inductors. In order to reduce the volume of magnetic components, magnetic integration of these two inductors is introduced in this chapter. First, the integration method of the two inductors of an LCL filter is proposed, and the magnetic circuit model of integrated inductors is built.
Xinbo Ruan   +5 more
openaire   +1 more source

Grid Impedance Estimation via Excitation of $LCL$-Filter Resonance

IEEE Transactions on Industry Applications, 2007
Inverters adopted in distributed power generation, active filter, and uninterruptible power supply are often connected to the grid through an inductance-capacitor-inductance (LCL) filter. The impedance of the LCL filter has a typical frequency characteristic with a resonance peak.
LISERRE, Marco   +2 more
openaire   +1 more source

Resonance Damping Methods of LCL Filter

2017
The control challenges of LCL-type grid-connected inverter arise from the resonance problem. At the resonance frequency, the LCL filter resonance causes a sharp phase step down of −180° with a high resonance peak. This resonance peak would easily lead to system instability and should be damped.
Xinbo Ruan   +5 more
openaire   +1 more source

Compact Genetic Algorithm for Designing LCL Filter

Power and Energy Systems, 2013
Proceedings of the IASTED International Conference Power and Energy Systems (AsiaPES 2013) April 10 - 12, 2013 Phuket ...
Puriwat Sarnthoy, Somyot Kaitwanidvilai
openaire   +1 more source

LCL Filter Based Solar Photovoltaic Distributed Generation System

2018 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES), 2018
Power generation form renewable energy sources have gained prominent importance now a days due to its abundant availability and zero carbon dioxide emission nature. The interface of converters has become very vital in transferring the power from energy sources such as wind, solar to the grid.
Sudhansu Sekhar Das, Aurobinda Panda
openaire   +1 more source

Design of LCL filter for wind power inverter

2010 World Non-Grid-Connected Wind Power and Energy Conference, 2010
An LCL filter is more and more widely used in wind power inverters. However, it may easily result in instability due to resonance, which makes it difficult for stability control without damping. A voltage oriented control strategy under the dq synchronization reference frame is adopted based on the mathematical model of the three-phase inverter for ...
Xing Wei   +3 more
openaire   +1 more source

PWM rectifier based on LCL filter parameter optimisation

International Journal of Industrial and Systems Engineering, 2014
In order to resolve the shortcomings of traditional single L-filter dynamic performance, LCL filter is introduced to PWM rectifier, which has a smaller inductance value and a good filtering effect. A new method PWM rectifier based on LCL filter parameter optimisation is proposed in this paper.
Bo Fan, Jiexin Pu, Gang Liu
openaire   +1 more source

Controlled single-phase current source with LCL filter

2014 ELEKTRO, 2014
This study proposes control algorithm for controlled single-phase current source. The power circuit of single-phase current source uses LCL type filter instead of a traditional L filter. The main advantage of LCL filter is lower current ripple, but it is necessary to use the advanced current control.
Vojtech Blahnik   +3 more
openaire   +1 more source

Home - About - Disclaimer - Privacy