Results 111 to 120 of about 22,404 (259)

Control strategy of LCL-type three-phase photovoltaic grid connected inverter

open access: yesJournal of Measurement Science and Instrumentation, 2019
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed
WANG Si-hua, WANG Jin-qiang
doaj  

Manufacturing and clinical applications of non‐CAR‐T immune effector cells

open access: yes
Transfusion, EarlyView.
Thane Kubik   +2 more
wiley   +1 more source

Capacitor Current Feedback-Based Active Resonance Damping Strategies for Digitally-Controlled Inductive-Capacitive-Inductive-Filtered Grid-Connected Inverters

open access: yesEnergies, 2016
Inductive-capacitive-inductive (LCL)-type line filters are widely used in grid-connected voltage source inverters (VSIs), since they can provide substantially improved attenuation of switching harmonics in currents injected into the grid with lower cost,
Iman Lorzadeh   +4 more
doaj   +1 more source

An Integrated Design Approach for LCL-Type Inverter to Improve Its Adaptation in Weak Grid

open access: yesEnergies, 2019
To improve the robustness of grid-connected inverter against grid impedance in a weak grid an integrated design method of LCL-filter parameters and controller parameters is proposed.
Chen Zheng   +7 more
doaj   +1 more source

Automation of Data Collection for Measuring The Quality of E-Commerce [PDF]

open access: yes, 2013
The research aims to help managers in information gathering web log visitors based on traffic data, building automation data for determining the needs of e-Commerce extensibility, and design of information systems in the process of database interaction ...
Andi, Gunawan   +2 more
core  

A New LCL Filter Design Method for Single-Phase Photovoltaic Systems Connected to the Grid via Micro-Inverters

open access: yesTechnologies
This paper aims to propose a new sizing approach to reduce the footprint and optimize the performance of an LCL filter implemented in photovoltaic systems using grid-connected single-phase microinverters.
Heriberto Adamas-Pérez   +5 more
doaj   +1 more source

Grid‐tied PEMFC power conditioning system based on capacitor voltage thorough feedback procedure in a weak and harmonics‐polluted network

open access: yesEnergy Science & Engineering
Proton exchange membrane fuel cells (PEMFC) have been noticed by researchers due to their high efficiency, low pollution, and high‐power density in distributed generation systems.
Majid Hosseinpour   +2 more
doaj   +1 more source