Results 151 to 160 of about 3,181 (183)
Some of the next articles are maybe not open access.
Design of LCL filter for wind power inverter
2010 World Non-Grid-Connected Wind Power and Energy Conference, 2010An LCL filter is more and more widely used in wind power inverters. However, it may easily result in instability due to resonance, which makes it difficult for stability control without damping. A voltage oriented control strategy under the dq synchronization reference frame is adopted based on the mathematical model of the three-phase inverter for ...
Xing Wei +3 more
openaire +1 more source
Spread Spectrum Modulation for LCL Filter Design
2019 20th International Symposium on Power Electronics (Ee), 2019The LCL filter is often the bulkiest component in grid-tied converters, which is designed to satisfy the grid harmonic standards such as IEEE519. To reduce the filter requirement, application of the spread spectrum modulation (SSM) to LCL filter design is investigated in this paper.
Ki-Bum Park +2 more
openaire +1 more source
Adaptive current control for grid-connected converters with LCL-filter
2009 35th Annual Conference of IEEE Industrial Electronics, 2009This paper presents a discrete-time adaptive current controller for grid-connected pulse width modulation voltage source converters with LCL filter. The main attribute of the proposed current controller is that, in steady state, the damping of the LCL resonance does not depend on the grid characteristic since the adaptive feedback gains ensure a ...
Jorge Rodrigo Massing +3 more
openaire +2 more sources
Development of an LCL filter for a residential Microgrid system
2015 International Conference on Advances in Electrical Engineering (ICAEE), 2015Energy crisis is becoming one of the major challenges in today's world due to increased energy demand and at the same time decreased energy resources. Energy from renewable sources can never be exhausted. They cause less emission and therefore stand out as a potentially viable source of clean and limitless energy.
Tabassum Perveen Ananna +5 more
openaire +1 more source
Grid-connected voltage source converters (VSCs) frequently implement third-order LCL switching ripple filters due to their superior high-frequency harmonic attenuation and compact sizing compared to standard L or LC filters. However, LCL combinations introduce severe resonance peaks that threaten control loop stability.
openaire +1 more source
openaire +1 more source
Comparison of efficiency of Double Conversion UPS with LC, LCL and LCL with damping resistor filters
2021 IEEE Conference on Energy Conversion (CENCON), 2021Robinson Kong +2 more
openaire +1 more source
A novel passive damping LCL-filter for active power filter
2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific), 2014null Cuili Chen +4 more
openaire +1 more source
Critical Damping Ratio to Ensure Design Efficiency and Stability of LCL Filters
IEEE Transactions on Power Electronics, 2021Weiyu Tang, Ke Ma, Yubo Song