Results 71 to 80 of about 86,878 (224)
ABSTRACT Background Leadless pacemakers (LPMs) have been shown to reduce complications compared with conventional transvenous pacing. Transfemoral venous access (FA) is the standard implantation approach; however, the transjugular approach (JA) has recently emerged as an alternative strategy, but comparative evidence remains limited.
Federico Giannino +11 more
wiley +1 more source
An 87-year-old man developed delayed cardiac tamponade 55 min after leadless pacemaker implantation and recurrent pericardial effusion 20 days later. Electrocardiogram-gated enhanced cardiac computed tomography revealed that the leadless pacemaker tines ...
Takafumi Oka, MD, PhD +5 more
doaj +1 more source
ABSTRACT Helix‐fixed leadless pacemaker delivery can be challenging after tricuspid annuloplasty with a rigid ring. An 80‐year‐old woman with prior mitral valve repair, tricuspid annuloplasty (26‐mm MC ring), and Maze III surgery presented with syncope due to atrial fibrillation with a slow ventricular response. Standard maneuvers failed to advance the
Yuya Nakamura +5 more
wiley +1 more source
Fluoroscopic predictors of successful mid‐septal Micra implantation were evaluated using computed tomography confirmation. Among fluoroscopic parameters assessed in the left anterior oblique view, the presence of an α‐loop shape of the delivery catheter was independently associated with mid‐septal implantation.
Misun Pak +3 more
wiley +1 more source
Background Leadless pacemaker therapy is associated with a significant reduction in lead-related complication rate compared to conventional transvenous single chamber pacemaker therapy.
Koushan Kouranloo +4 more
doaj +1 more source
Soft, Flexible, and Stretchable Platforms for Tissue‐Interfaced Bioelectronics
Bio‐integrated electronics provide mechanically compliant and stable interfaces with soft biological tissues. Representative applications include neural interfaces, wet‐organadhesive electronics, and skin‐interfaced devices. E represents Young´s modulus and ε represents strain.
Kento Yamagishi +3 more
wiley +1 more source
Leadless pacemakers provide a potential alternative to conventional transvenous pacemakers for patients undergoing high-risk transcatheter valve replacement procedures.
Enes Elvin Gul +4 more
doaj +1 more source
Background The atrial switch procedure is accompanied by a very high rate of sinus node dysfunction. Baffle stenosis is a common problem with transvenous pacemaker leads in this scenario. Case Summary We present a first-in-human case of a leadless pacer (
Dustin A. Staloch +2 more
semanticscholar +1 more source
First Report on Atrial Leadless Pacing in a Lateral Tunnel Fontan Patient
ABSTRACT Introduction No reports on atrial leadless pacing have been demonstrated in patients with the Fontan palliation. We present the case of a patient with a Lateral tunnel Fontan palliation with leadless pacing system for symptomatic bradycardia in the setting of sinus node dysfunction. Methods After internal review board approval, a retrospective
Daniel Cortez +2 more
wiley +1 more source
New-generation Leadless Pacemaker Implantation: First Procedures in Central Asia
In this article, we describe our first experiences implanting the AVEIR VR leadless pacemaker (Abbott) in Kazakhstani patients, a significant step in the development of this technology in Central Asia. This case series includes five male patients, with a
Abay Bakytzhanuly +2 more
doaj +1 more source