Results 261 to 270 of about 474,823 (307)
Some of the next articles are maybe not open access.

Visualization of leakage flow in buildings

Optics & Laser Technology, 1989
Abstract Leakage flow around a window has been visualized with the aid of holographic interferometry. The experiments were performed during winter.
K.-E Peiponen   +2 more
openaire   +1 more source

Leakage Flow Over Shrouded Turbine Blades

Volume 3: Heat Transfer; Electric Power; Industrial and Cogeneration, 2000
In this paper the flows over shrouded turbine blades with single, double, and triple tip seals were simulated by using the two-dimensional Reynolds-averaged Navier-Stokes equations and a compressible k-ε turbulence model. A multi-zone technique was used to generate the grids in the complex flow channel.
Yumin Xiao, R. S. Amano
openaire   +1 more source

Leakage characteristics of plug flow in the case of pipe leakage

The Canadian Journal of Chemical Engineering
Abstract In order to study the changes in two‐phase flow parameters after pipeline damage and the impact of gas injection on water leakage from damaged pipelines, experimental and simulation studies were conducted on the damaged pipelines.
Tao Ren   +4 more
openaire   +1 more source

Control of leakage flows using periodic excitation

Fluids 2000 Conference and Exhibit, 2000
Many flows can be characterized as leakage flows from high-pressure sides to lowpressure sides, resulting in increased inefficiency. This paper experimentally explores reducing leakage flows using periodic excitation. A synthetic jet actuator was used as the periodic excitation source in this experiment.
E. Kang, C. Tan, K. Breuer
openaire   +1 more source

Coupled Reservoir Flow Simulation: Fault Leakage Analysis

SPE Annual Technical Conference and Exhibition, 2009
Abstract Petroleum project costs may increase tremendously if wells need to be shut in or abandoned. A scenario where this possibility exists occurs in a reservoir hanging a major fault that connects the petroleum field to the seafloor.
L. G. Rodrigues   +2 more
openaire   +1 more source

Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan

Flow, Turbulence and Combustion, 2003
zbMATH Open Web Interface contents unavailable due to conflicting licenses.
Lee, GH, Baek, JH, Myung, HJ
openaire   +3 more sources

Tip Leakage Flow Characteristics Downstream of an Axial Flow Fan

Volume 1: Turbomachinery, 1996
The three-dimensional viscous flow characteristics and the complex vortex system downstream of the rotor of an industrial exial fan have been determined by an experimental investigation using hot-wire anemometer. Single-wire slanted and straight type probes have been rotated about the probe axis using a computer controlled stepper motor.
openaire   +1 more source

Tip Leakage Flow: Advanced Measurements and Analysis

22nd AIAA/CEAS Aeroacoustics Conference, 2016
Advanced measurements of a tip clearance flow are carried out in the large subsonic anechoic wind tunnel of the LMFA in Lyon. The experimental set-up is obtained by placing the airfoil between two plates into the potential core of a turbulent rectangular jet, the upper plate being the hub and the lower the casing.
Jacob, Marc   +3 more
openaire   +3 more sources

Tip Leakage Flow In a Mixed-flow Pump

The numerical results used to describe the special flow features/characteristics of the mixed-flow pump in this chapter were obtained by employing the computational methodology described in Chapter 3 which includes the pump model, mesh generation, turbulence models and their near wall treatment, and the boundary conditions.
Wei Li   +4 more
openaire   +1 more source

Through Flow Analysis and Leakage Flow of a Regenerative Pump

Transactions of the Korean Society of Mechanical Engineers B, 2003
Flows in a regenerative pump were calculated for several flow-rates, using the CFX-Tascflow. The calculated results show the vortex structure in the impeller and side channel. The predicted performance shows considerable discrepancy from the measured values for low flow rates. Main source of the difference is the leakage flow of pump strongly affecting
openaire   +1 more source