Results 241 to 250 of about 37,143 (302)
Mitochondrial Dysfunction at the Intersection of CKM Syndrome: Molecular Mechanisms and Path-to-Target Therapies. [PDF]
Kuo YJ +4 more
europepmc +1 more source
Exploring the diversity of the CO2-concentrating mechanism in different C4 subtypes. [PDF]
Baccolini C +9 more
europepmc +1 more source
Implementing Nitrogen Vacancy Center Quantum Sensor Technology for Magnetic Flux Leakage Testing. [PDF]
Villing J +4 more
europepmc +1 more source
Performance evaluation of cellulose triacetate and cellulose diacetate hybrid membranes with carbon nanotube (CNT) for sustainable slaughterhouse wastewater treatment via forward osmosis. [PDF]
Moustafa HMA +4 more
europepmc +1 more source
The influence of multidirectional leakage flux on transformer core losses [PDF]
In a power transformer, the leakage flux enters the laminations of the iron core in different directions. Depending on the orientation of the leakage flux, it can add eddy current and hysteresis losses to the well-documented losses caused by the main ...
Arne Nysveen, N Magnússon
exaly +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
A study of magnetic flux-leakage signals
Journal of Physics D: Applied Physics, 1998Magnetic flux-leakage (MFL) measurement is the most widely used non-destructive technique for in-service inspection of oil and gas pipelines. The effect of line-pressure-induced hoop stress on MFL signals has been studied for an electrochemically milled pit (50% penetration) in a 9 mm thick steel pipe wall.
K Mandal, D L Atherton
openaire +2 more sources
Optimisation of the flux distribution in magnetic flux leakage testing
Insight - Non-Destructive Testing and Condition Monitoring, 2009In the magnetic flux leakage (MFL) non-destructive testing technique there are many factors that cause degeneration of the measured signal. One of these factors is non-uniformity of the magnetic flux inside the sample under test. Uniformity of the magnetic flux results in smoother and more predictable signals from various flaw types and also a ...
E Norouzi, H Ravanbod
openaire +1 more source
Leakage flux in a single phase transformer
Journal of Magnetism and Magnetic Materials, 1984Abstract The effects of aluminium magnetic shielding and mild steel magnetic shunts on the leakage flux in the steel tank of a single-phase 50 Hz low power transformer have been investigated.
H.G. Kendall, A. Basak
openaire +1 more source

