Results 191 to 200 of about 3,748,215 (287)

Zero‐Fluoroscopy Ablation Methods for Atrial Fibrillation: A Systematic Review and Meta‐Analysis

open access: yesPacing and Clinical Electrophysiology, EarlyView.
Central illustration. Schematic comparison of conventional fluoroscopy guided ablation (left) and zero fluoroscopy ablation (right), enabled by electroanatomical mapping and intracardiac echocardiography for catheter navigation without X ray. The study selection process is summarized (133 records identified; 12 studies included, total n = 1998 ...
Marwan Shawki   +5 more
wiley   +1 more source

Navigating the Zero Fluoroscopy Frontier: Current Tools, Evidence and Future Directions in Electrophysiology Procedures

open access: yesPacing and Clinical Electrophysiology, EarlyView.
Graphical Abstract ABSTRACT Fluoroscopy has traditionally been the mainstay imaging technique for guidance during electrophysiology (EP) ablation procedures. The numerous disadvantages associated with radiation exposure for both operators and patients have created the need for zero‐fluoroscopy (ZF) approaches. Today, electrophysiologists have access to
Dimitrios Kotzadamis   +6 more
wiley   +1 more source

Internal Jugular Vein as an Alternative Access for Pacemaker Implantation: A Mostly Left IJ Case Series

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background Leadless pacemakers traditionally rely on femoral venous access, which may be limited in patients with unfavorable IVC anatomy, prior interventions, or situations where preserving femoral access is preferred. Internal jugular (IJ) access offers an alternative route, but real‐world data on IJ implantation of single‐ and dual‐chamber ...
Maya Asami Takagi   +3 more
wiley   +1 more source

Ventricular Synchrony in Targeted Right Ventricular Septal Pacing: A Prospective Paired Comparison to Apical Placement

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background/Objectives Right ventricular (RV) apical pacing, the standard pacing approach, often induces ventricular dyssynchrony, potentially impairing cardiac function. This study aims to investigate whether targeted RV septal pacing, guided by functional electrophysiological feedback during implantation, reduces ventricular dyssynchrony ...
Bianca Iulia Catrina   +5 more
wiley   +1 more source

Left atrial strain importance in atrial fibrillation screening process

open access: yesAnnals of Cardiothoracic Surgery
Inciardi, Riccardo M   +2 more
openaire   +3 more sources

A Reassessment of Prophylactic Antibiotics in Low‐Infection‐Risk Electrophysiology Procedures

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Certain electrophysiology (EP) procedures are associated with minimal tissue disruption and do not involve permanent transvenous leads. As a result, these interventions carry a lower risk of device‐ or procedure‐related infection. These procedures include placement of implantable cardiac monitors, leadless pacemakers, and left atrial appendage
Rahel M. Sileshi   +14 more
wiley   +1 more source

Home - About - Disclaimer - Privacy