Results 231 to 240 of about 4,399,583 (292)

Predicting Device‐Induced Platelet Damage in Assisted Circulation Using a New Biophysical Model and Experimental Validation

open access: yesArtificial Organs, EarlyView.
Quantitative assessment of a newly proposed CFD‐based biophysical model for predicting device‐induced platelet damage by circulatory assist devices was performed. The new model preserved the relative trends observed previously with the power‐law formulation across a range of clinically relevant pump operating conditions, while demonstrating improved ...
Anik Tarafder   +3 more
wiley   +1 more source

Predicting Sepsis in Heart Failure Patients Supported by Left Ventricular Assist Devices: The Role of VE-Cadherin and ADAM10. [PDF]

open access: yesInt J Mol Sci
Li S   +12 more
europepmc   +1 more source

Prevention and Management of Driveline Infections in Ventricular Assist Device Patients: The DESTINE 2.0 Staging Proposal and Expert Recommendations

open access: yesArtificial Organs, EarlyView.
DESTINE 2.0 decision flowchart: stage‐based assessment and management of driveline exit‐site disorders. The flowchart provides a simplified decision‐support tool for the stage‐based evaluation and management of driveline exit‐site disorders in LVAD patients, intended as a practical complement to the staging pyramid (Figre 2) and the detailed staging ...
Alexander M. Bernhardt   +7 more
wiley   +1 more source

Multiscale Modeling of a Geometrically Tunable Shunt for Growing Pediatric Patients With Single Ventricle Physiology

open access: yesArtificial Organs, EarlyView.
Here we investigated the development of a geometrically tunable blood for patients with single ventricle physiology. Two multiscale cardiovascular models were customized and implemented at timepoints spanning across the beginning and end of the shunt‐use period.
Ellen E. Garven   +4 more
wiley   +1 more source

A Detailed Weaning Protocol to Assess Cardiac Recovery in Patients With Left Ventricular Assist Devices. [PDF]

open access: yesJACC Case Rep
Kader R   +6 more
europepmc   +1 more source

Temporary Right Ventricular Mechanical Circulatory Support Devices in Acute Right Ventricular Failure and Cardiogenic Shock: A Cross‐Device Systematic Review and Single‐Arm Meta‐Analysis

open access: yesArtificial Organs, EarlyView.
Among selected patients receiving temporary right ventricular support, pooled survival to discharge was 60.4%, and separately pooled successful weaning was 60.6%. These descriptive estimates from 106 heterogeneous observational studies, predominantly involving concurrent left‐sided or biventricular support, cannot establish treatment benefit or ...
Hussein Elghazaly   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy