Results 81 to 90 of about 2,971,220 (284)
Perfusion of the interventricular septum during ventilation with positive end-expiratory pressure (PEEP) [PDF]
Objective: To determine whether regional hypoperfusion of the interventricular septum occurs during ventilation with positive end-expiratory pressure. Design: Animal study. Animals: Anesthetized, closed chest dogs (n = 8).
Schosser, Rudolf +6 more
core +1 more source
The operative goals of the repair of postinfarction left ventricular aneurysms are to correct the size and geometry of the left ventricle in order to reduce wall tension and paradoxical movement and to improve the systolic function. Endoventriculoplasty
Gürsel Levent Oktar +3 more
doaj
Impact of Prehypertension on Left Ventricular Structure, Function and Geometry
Awareness of prevalence, determinants, and prognosis of asymptomatic untreated prehypertension is still lacking especially in India and subcontinent. The present study was to assess the effects of prehypertension on structure, function and geometrical pattern of left ventricle on the basis of left ventricular mass (LVM), left ventricular mass indexed ...
Jugal Kishore Bajpai +5 more
openaire +3 more sources
Smart Bioinks for 4D Bioprinting: Requirements, Design, and Applications
Smart bioinks empower 4D‐bioprinted constructs to dynamically adapt and remodel in response to stimuli, effectively biomimicking native tissues. Artificial Intelligence (AI) and Machine Learning (ML) play a guiding role in their rational design by optimizing relevant properties.
Shangsi Chen +11 more
wiley +1 more source
Transverse left ventricular band
Left ventricular band has been considered a vestigial entity for quite a long time. Their incidence is quite common in our day to day practise but their real function is yet to be understood. We performed a case series of 5 patients with left ventricular
Manoj Kumar Dubey +3 more
doaj +1 more source
Thickness‐Gradient Liquid Metal Connectors for Seamless Electrophysiological Sensors
Thickness‐gradient liquid metal interfaces with elastomeric substrates enable seamless integration between ultrathin skin‐conformal electrodes and external interconnects. The mechanically compliant connector reduces interfacial mismatch and supports stable ECG/EMG monitoring under bending and motion.
Jinyoung Kim +3 more
wiley +1 more source
Background Most patients with implantable cardioverter-defibrillator (ICD) implantation fail to utilize the device resulting in increasing societal costs and patient exposure to device morbidity.
Shiro Nakamori +4 more
doaj +1 more source
Retrospective Grid Cells in the Medial Entorhinal Cortex Encode Past Paths During Spatial Navigation
Retrospective grid cells are identified in the medial entorhinal cortex, with spatial firing patterns that become most grid‐like when activity is projected onto recently traversed locations. Their coding loses spatial precision in darkness and is disrupted during assisted movement, indicating that entorhinal representations incorporate recent path ...
Ruojin Liu +10 more
wiley +1 more source
Comparative evaluation of left ventricular mass regression after aortic valve replacement: a prospective randomized analysis [PDF]
Background: We assessed the hemodynamic performance of various prostheses and the clinical outcomes after aortic valve replacement, in different age groups.
Wood Jeffrey P +11 more
core +2 more sources
Salvianolic acid A (SAA) selectively induces senescent vascular smooth muscle cell apoptosis, alleviating atherosclerosis. Mechanistically, SAA targets heat shock protein 90 alpha (HSP90α) to disrupt the protein inase B (AKT)‐PRKR‐Like Endoplasmic Reticulum Kinase (PERK) scaffold, driving ubiquitin‐proteasome‐dependent AKT degradation.
Xiuya Guan +8 more
wiley +1 more source

