Results 81 to 90 of about 2,022,016 (225)
A Comparative Study of Right Ventricular Apical Pacing and Right Ventricular Septal Pacing [PDF]
Objective: Assessment of cardiac function by the assessment of ventricular pacing and right ventricular apex pacing. Method: Analysis of 30 patients with VVI pacemaker (pacing RVA, right ventricular apical pacing RVS 15 cases) was analyzed, and the ...
Chen, Zhili, Jiang, Changhao, Ni, Shimao
core +1 more source
ABSTRACT Introduction In patients with ischemic cardiomyopathy (ICM), recurrent VF may be treated with catheter ablation by targeting triggering premature ventricular complexes (PVCs) and/or ventricular scar homogenization. Data on optimal ablation strategies in patients with non‐ischemic cardiomyopathy (NICM) remain limited.
Kenji Hashimoto +2 more
wiley +1 more source
Exercise-induced left septal fascicular block: an expression of severe myocardial ischemia [PDF]
The electrocardiogram (ECG) criteria for the left septal fascicular block (LSFB) are not universally accepted and many other denominations can be seen in literature: focal septal block, septal focal block, left septal fascicular block, left anterior ...
Beatriz Moreira Ayub Ferreira +7 more
core
ABSTRACT Introduction Electrogram peak‐to‐peak voltage depends on atrial wall structure and mapping configuration. We evaluated the relationship between computed tomography–derived atrial wall thickness, intramyocardial fat, myocardial muscle thickness, and electrogram voltage obtained with omnipolar, bipolar, and unipolar mapping.
Cecilia Granata +21 more
wiley +1 more source
IntroductionLeft bundle branch pacing (LBBP) in bipolar pacing with anodal capture produces a more balanced ventricular activation than conventional unipolar pacing but need high pacing output.
Hao Wu +4 more
doaj +1 more source
ABSTRACT Background Pulsed field ablation (PFA) is an emerging non‐thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited. Objective To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real‐world US registry ...
Narut Prasitlumkum +22 more
wiley +1 more source
Double orifice mitral valve associated with Ventricular Septal Defect in an infant : case report [PDF]
Double orifice mitral valve (DOMV) is an uncommon anomaly characterized by a mitral valve with a single fibrous annulus with two orifices opening into the left ventricle.
Taksande, Amar M. +2 more
core
Focus on right ventricular outflow tract septal pacing [PDF]
SummaryExperimental and clinical studies have shown that right ventricular apical pacing may result in long-term deleterious effects on account of its negative impact on left ventricular remodeling through desynchronization.
Laurence, Bisch +7 more
core +1 more source
An analysis of defibrillation and cardiac resynchronization therapy strategies in patients with failing systemic right ventricles [PDF]
Includes bibliographical references (leaves 52-56).The expanding application of cardiac resynchronization (CRT) and implantable cardioverter-defibrillator therapy (lCD) to include patients with congenital heart disease requires careful evaluation of ...
Michael, Kevin A
core +1 more source
Background Conduction system pacing (CSP) is a novel technique that involves pacing the His-Purkinje system instead of the traditional right ventricular (RV) apex.
Luuk H.G.A. Hopman +4 more
doaj +1 more source

