Results 81 to 90 of about 89,869 (345)
Inadvertent trypan blue staining of posterior capsule during cataract surgery associated with Argentinian flag event [PDF]
Trypan blue is common in visualizing the anterior capsule during cataract surgery. Inadvertent staining of the posterior capsule during phacoemulsification is a rare complication and there are few reports in the literature.
Alapati, Neeti M +3 more
core +4 more sources
Fabrication, Properties, and Applications of Scaffolds for Bone Tissue Regeneration
This review explores cutting‐edge biomaterials and fabrication techniques for scaffolds in bone tissue regeneration. It conducts a critical comparison of various strategies, meticulously analyzes the key contradictions in the field, and outlines an integrated development path spanning from biomaterial selection to clinical application, while ...
Shangsi Chen, Min Wang
wiley +1 more source
A Case Report of Implantation of the Multifocal Intraocular Lens in a Patient with Marfan’s Syndrome
Purpose: To demonstrate a case report of successful implantation of multifocal IOL in patients with Marfan syndrome.Materials and methods. A young patient with Marfan’s syndrome asked to the clinic.
S. V. Shukhaev +2 more
doaj +1 more source
Vault changes in eyes with a vertically implanted implantable collamer lens [PDF]
Masayuki Ouchi
openalex +1 more source
Transducers convert physical signals into electrical and optical representations, yet each mechanism is bounded by intrinsic trade‐offs across bandwidth, sensitivity, speed, and energy. This review maps transduction mechanisms across physical scale and frequency, showing how heterogeneous integration and multiphysics co‐design transform isolated ...
Aolei Xu +8 more
wiley +1 more source
Purpose: The purpose is to study the change in the contact of the IOL with the posterior capsule using intraoperative SD-OCT before and after implantation of the CTR post implantation of the IOL in the capsular bag.
Naren Shetty +6 more
doaj +1 more source
Here, it is shown that focused ion beam induced deposition (FIBID) using helium and neon ions enables advanced high‐resolution 3D nanoprinting achieving precise multimaterial architectures and engineered internal voids. Thus, FIBID with finely focused noble gas ion species is presented as a unique platform for designing functional nanomaterials for ...
Frances Isabel Allen
wiley +1 more source
Cataract surgery in eyes with filtered primary angle closure glaucoma. [PDF]
PurposeTo evaluate the effect of cataract surgery on intraocular pressure (IOP) in filtered eyes with primary angle closure glaucoma (PACG).MethodsIn this prospective interventional case series, 37 previously filtered eyes from 37 PACG patients with mean
Amini, Heydar +7 more
core +2 more sources
This review presents recent progress in vision‐augmented wearable interfaces that combine artificial vision, soft wearable sensors, and exoskeletal robots. Inspired by biological visual systems, these technologies enable multimodal perception and intelligent human–machine interaction.
Jihun Lee +4 more
wiley +1 more source
Three-year experience of posterior chamber phakic intraocular lens implantation in the high myopia correction [PDF]
I.F. Saliev +2 more
openalex +1 more source