Results 31 to 40 of about 221,747 (248)
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa+4 more
wiley +1 more source
Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities
Abstract The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net
Tatsuhiro Gotanda+9 more
wiley +1 more source
Synchronization of light flash with the irradiation pulse in proton beam therapy: A case report
The correlation between sensory light flash and proton beam delivery was evaluated by measuring the timing of pulse beam delivery and light flash sensing using an event recorder in an 83-year-old patient receiving proton beam therapy (PBT) for ...
Takashi Saito+11 more
doaj
Automated rapidplan model validation using Eclipse scripting API
Abstract RapidPlan offers efficiency gains and quality improvements in treatment planning. Prior to its use in the clinic, it requires an extensive validation procedure in which established clinical plans and those generated by the model are compared. The manual iterative nature of this process is resource intensive, as numerous iterations are required
Bradley Beeksma+2 more
wiley +1 more source
Abstract Purpose The aim of this work was to report on the optimization, commissioning, and validation of a beam model using a commercial independent dose verification software RadCalc version 7.2 (Lifeline Software Inc, Tyler, TX, USA), along with 4 years of experience employing RadCalc for offline and online monitor unit (MU) verification on the ...
Urszula Jelen+3 more
wiley +1 more source
Cancer surgery is aimed at complete tumor resection and accurate lymph node detection. However, numerous blood vessels are distributed within the tumor, and the colors of the tumor, blood vessels, and lymph nodes are similar, making observations with the
Jeongmin Seo+6 more
doaj +1 more source
The study presents an efficient simulation approach for the polymer laser powder bed fusion process polymers process, validated with polyamide 12, polyamide 6, and polyetherketoneketone. It shows that inter layer time affects part density, with 90s yielding dense parts.
Claas Bierwisch+4 more
wiley +1 more source
Additive manufacturing of magnesium alloys by laser is difficult because the melting point of the oxide layer is much higher than the evaporation temperature of the metal underneath. Making the oxide layer thinner can solve this problem. Alloying magnesium with strontium makes the oxide layer thinner, especially at 0.5 wt%.
Elmar Jonas Breitbach+8 more
wiley +1 more source
Simulation of Inhomogeneous Refractive Index Fields Induced by Hot Tailored Forming Components
This article presents a simulation model for simulating inhomogeneous refractive index fields (IRIF) in hot‐forged components, accounting for thermal influences and complex geometries. Through this simulation, a priori knowledge about the propagation of the IRIF can be obtained, allowing for the positioning of the component or an optical measurement ...
Pascal Kern+3 more
wiley +1 more source
Audio encryption using polarized light beam
In recent years, the security of audio data has become paramount in terms of personal information, national security, and forensic evidence. However, most reported systems use digital algorithms and lack their implementation in the optical domain, which ...
Allarakha Shikder+4 more
doaj +1 more source