Results 251 to 260 of about 429,968 (291)
Some of the next articles are maybe not open access.

1922 Developments in autovalve lightning arresters

Journal of the American Institute of Electrical Engineers, 1923
The work done in the past year in developing commercial forms of lightning arresters based on the ``autovalve'' principle is reported. Fundamental data given by Dr. Slepian at the 1922 Midwinter Convention are briefly reviewed. The balance of the paper deals with new material and covers further research, development and test.
openaire   +4 more sources

Lightning Arrester Discharge Currents

Nature, 1948
DURING the last five years an investigation has been made of the discharge currents of a number of 38,000-volt lightning arresters. The transmission system on which these arresters were installed is operated with its neutral point earthed through Peterson coils; the lines are not equipped with overhead ground wires.
openaire   +2 more sources

Evaluation of Absorption Energy of Surge Arrester on Medium-Voltage Lines by Lightning to Wind Turbine in Winter

2019 11th Asia-Pacific International Conference on Lightning (APL), 2019
In recent years, the rate of burnout accidents due to excess energy capacity of surge arresters on medium-voltage distribution lines is increasing in lightning accidents.
M. Asano, K. Michishita, S. Yokoyama
semanticscholar   +1 more source

Transient Electric Field Calculation of Zinc oxide arrester under Lightning Impulse Voltage

Conference on Electrical Insulation and Dielectric Phenomena, 2018
For a fast changing excitation like lightning impulse voltage which is applied to a zinc oxide arrester, its waveform in frequency domain contains many different frequency harmonic components and its response is the sum of the response of each harmonic ...
Shiyi Zhou   +6 more
semanticscholar   +1 more source

New Principles in the Design of Lightning Arresters

Transactions of the American Institute of Electrical Engineers, 1907
The installation of lightning arresters is of the nature of an insurance. A certain percentage of the cost of the apparatus can reasonably be invested as a safeguard in protecting the apparatus. Furthermore, a percentage of the income can also be invested in protective apparatus as an insurance against interruption of service.
openaire   +2 more sources

Prototype of multi-chamber loop-type arrester for 110 kV OHL lightning protection.

International Conference on Logic Programming, 2018
Our article describes in steps development of multichamber arrester for protection of 110 kV overhead power lines from tripouts caused by lightning impact.
G. Podporkin   +4 more
semanticscholar   +1 more source

A study of degradation characteristics and diagnostic method of lightning surge arrester for 6.6kV power distribution lines

International Conference on Logic Programming, 2018
Lightning surge arresters with a series gap are used in Japan for 6.6 kV distribution lines and are primarily comprised of a metal oxide varistor (MOV) with a series gap, and they are sealed by a metal lid and a sealing rubber. The degradation of the MOV
Y. Yoneda   +3 more
semanticscholar   +1 more source

Influence of Lightning Channel Impedance and Nonuniform Tower Footing Resistance Distribution on Line Surge Arrester Energy Duty

IEEE PES Innovative Smart Grid Technologies Conference Europe, 2018
This paper describes a detailed transmission line model for a transient analysis. Line surge arrester energy sharing and importance of complete transmission line modelling is explained.
S. Grebović, N. Oprašić
semanticscholar   +1 more source

Analysis of lightning arrester operating current based on multidimensional neural network for transmission lines

Evolutionary Intelligence, 2022
Dong Yang   +4 more
semanticscholar   +1 more source