Results 261 to 270 of about 429,968 (291)
Revised American standard for lightning arresters [PDF]
The revised American Standard for lightning arresters for a-c power circuits from 120-volt through 230-kv circuits is discussed.
openaire +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
The Power Interruption Testing of Lightning Arresters
Transactions of the American Institute of Electrical Engineers, 1951A special surge circuit has been developed for use in power interruption testing of lightning arresters. This circuit consists of a power source, a surge circuit, and an impulse timing circuit.
openaire +2 more sources
Development and applications of lightning arresters for transmission lines
IEEE Transactions on Power Delivery, 1989A lightning arrester with a series gap for transmission lines has been developed to prevent faults due to lightning. It has shown excellent performance since 1986 on 77 kV service lines in heavy lightning regions. A 275 kV lightning arrester has also been developed, and a field test was started on a service line in 1988.
T. Irie+3 more
openaire +2 more sources
A protocol for selecting viable transmission line arrester for optimal lightning protection
Electric power systems research, 2023N. Ahmed, H. Illias, H. Mokhlis
semanticscholar +1 more source
Lightning Arrester Spark Gaps-II
Transactions of the American Institute of Electrical Engineers, 1920This paper describes a new form of high-voltage lightning arrester gap which has been called the ``impulse protective gap'' because of its particular effectiveness in protecting against line disturbances of steep wave front. The paper opens with a brief resume of some of the results of previous investigations of the subject of impulse voltages.
openaire +2 more sources
Distribution lightning arrester performance data
Electrical Engineering, 1937THE intelligent application of lightning arresters requires a knowledge of their performance characteristics under conditions which are likely to be encountered in service. Data have been presented relating to the impulse characteristics of insulation both as used on lines and in transformers.
A.M. Opsahl+13 more
openaire +2 more sources
Lightning Protection of Equipment with Remotely Mounted Lightning Arresters
Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 19581. The curves apply to any type of modern lightning arrester. Only the sparkover voltage has to be known; this should be obtained from the manufacturer. 2. When the arrester is between the equipment and the surge, the maximum voltage at the equipment approaches 200% of the arrester sparkover voltage.
openaire +2 more sources
Pellet type of oxide film lightning arrester
Journal of the American Institute of Electrical Engineers, 1923K. B. McEachron: The pellet arrester represents an extension of the oxide film principle in an ingenious manner. The problem of making, commercially, small pellets of lead peroxide, and coating them with litharge has been solved in a satisfactory manner.
openaire +3 more sources
Long-duration surge testing of lightning arresters
Electrical Engineering, 1951A METHOD OF long-duration surge-withstand design testing of station-type lightning arresters is proposed for consideration by the industry. The test method involves successive applications of a surge having an essentially constant magnitude and a duration measured in thousands of microseconds.
S. B. Howard+2 more
openaire +2 more sources
Thyrite A New Material for Lightning Arresters
Transactions of the American Institute of Electrical Engineers, 1930A new material has been developed which is peculiarly adapted for use in lightning arresters. It is physically similar to dry process porcelain and it can be made in any shape that can be successfully moulded. The manufacturing processes have been perfected so that the electrical and mechanical characteristics can be duplicated or varied as desired ...
openaire +2 more sources